Size-selective purification of hepatitis B virus-like particle in flow-through chromatography: types of ion exchange adsorbent and grafted polymer architecture

Hepatitis B virus-like particles expressed in Escherichia coli were purified using anion exchange adsorbents grafted with polymer poly(oligo(ethylene glycol) methacrylate) in flow-through chromatography mode. The virus-like particles were selectively excluded, while the relatively smaller sized host...

Full description

Saved in:
Bibliographic Details
Main Authors: Hon, Wei Ng, Fu, Micky Xiang Lee, Gek, Kee Chua, Gan, Bee Koon, Tan, Wen Siang, Chien, Wei Ooi, Siah, Ying Tang, Eng, Seng Chan, Beng, Ti Tey
Format: Article
Language:English
Published: Wiley 2018
Online Access:http://psasir.upm.edu.my/id/eprint/73901/1/Size-selective%20purification%20of%20hepatitis%20B%20virus-like%20particle%20in%20flow-through%20chromatography%20types%20of%20ion%20exchange%20adsorbent%20and%20grafted%20polymer%20architecture.pdf
http://psasir.upm.edu.my/id/eprint/73901/
https://onlinelibrary.wiley.com/doi/abs/10.1002/jssc.201700823
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Hepatitis B virus-like particles expressed in Escherichia coli were purified using anion exchange adsorbents grafted with polymer poly(oligo(ethylene glycol) methacrylate) in flow-through chromatography mode. The virus-like particles were selectively excluded, while the relatively smaller sized host cell proteins were absorbed. The exclusion of virus-like particles was governed by the accessibility of binding sites (the size of adsorbents and the charge of grafted dextran chains) as well as the architecture (branch-chain length) of the grafted polymer. The branch-chain length of grafted polymer was altered by changing the type of monomers used. The larger adsorbent (90 μm) had an approximately twofold increase in the flow-through recovery, as compared to the smaller adsorbent (30 μm). Generally, polymer-grafted adsorbents improved the exclusion of the virus-like particles. Overall, the middle branch-chain length polymer grafted on larger adsorbent showed optimal performance at 92% flow-through recovery with a purification factor of 1.53. A comparative study between the adsorbent with dextran grafts and the polymer-grafted adsorbent showed that a better exclusion of virus-like particles was achieved with the absorbent grafted with inert polymer. The grafted polymer was also shown to reduce strong interaction between binding sites and virus-like particles, which preserved the particles' structure.