Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath
CMOS-MEMS resonators have found a broad usage in mass sensing applications. They can be used to detect biomarkers in exhaled breath (EB) for screening of diseases. Damping is believed to hinder the performance of these resonators. This paper focuses on investigating effects of damping in natural fre...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012008377&doi=10.1109%2fICIAS.2016.7824037&partnerID=40&md5=740228e475a1a7e0c73ed91fb0aa167d http://eprints.utp.edu.my/20171/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.20171 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.201712018-04-22T14:44:19Z Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath Rabih, A.A.S. Dennis, J.O. Khir, M.H.Md. Ahmed, M.G. CMOS-MEMS resonators have found a broad usage in mass sensing applications. They can be used to detect biomarkers in exhaled breath (EB) for screening of diseases. Damping is believed to hinder the performance of these resonators. This paper focuses on investigating effects of damping in natural frequency, mass sensitivity and displacement of a proposed resonator for biomarker detection in EB. The resonator is electrostatically actuated using parallel plate capacitor principle. Squeeze film damping was found to affect the resonator performance when the gap distance between the plates was varied as 5, 7, 9, 10 and 11 μm, in which 5 μm led the resonator to be overdamped. For the rest of gaps the resonator is underdamped. FEA simulation using CoventorWare was used to confirm the mathematical modeling of the resonator, in which results agree with the modeling within an acceptable percentage error of 5 . © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012008377&doi=10.1109%2fICIAS.2016.7824037&partnerID=40&md5=740228e475a1a7e0c73ed91fb0aa167d Rabih, A.A.S. and Dennis, J.O. and Khir, M.H.Md. and Ahmed, M.G. (2017) Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath. International Conference on Intelligent and Advanced Systems, ICIAS 2016 . http://eprints.utp.edu.my/20171/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
CMOS-MEMS resonators have found a broad usage in mass sensing applications. They can be used to detect biomarkers in exhaled breath (EB) for screening of diseases. Damping is believed to hinder the performance of these resonators. This paper focuses on investigating effects of damping in natural frequency, mass sensitivity and displacement of a proposed resonator for biomarker detection in EB. The resonator is electrostatically actuated using parallel plate capacitor principle. Squeeze film damping was found to affect the resonator performance when the gap distance between the plates was varied as 5, 7, 9, 10 and 11 μm, in which 5 μm led the resonator to be overdamped. For the rest of gaps the resonator is underdamped. FEA simulation using CoventorWare was used to confirm the mathematical modeling of the resonator, in which results agree with the modeling within an acceptable percentage error of 5 . © 2016 IEEE. |
format |
Article |
author |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.Md. Ahmed, M.G. |
spellingShingle |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.Md. Ahmed, M.G. Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
author_facet |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.Md. Ahmed, M.G. |
author_sort |
Rabih, A.A.S. |
title |
Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
title_short |
Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
title_full |
Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
title_fullStr |
Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
title_full_unstemmed |
Study of damping effect on CMOS-MEMS resonator for biomarker detection in exhaled breath |
title_sort |
study of damping effect on cmos-mems resonator for biomarker detection in exhaled breath |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012008377&doi=10.1109%2fICIAS.2016.7824037&partnerID=40&md5=740228e475a1a7e0c73ed91fb0aa167d http://eprints.utp.edu.my/20171/ |
_version_ |
1738656173770407936 |
score |
13.209306 |