Application of draw wire sensor in the tracking control of an electro hydraulic actuator system

A draw wire sensor is considered as a contact measurement method. It is normally used to measure the speed and position of a system. A draw wire sensor is convenient especially when a low cost solution and a small sensor dimension are desired. The objective of this paper is to describe the applicati...

Full description

Saved in:
Bibliographic Details
Main Authors: Salleh, S., Rahmat, M. F., Othman, S. M., Abidin, H. Z.
Format: Article
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/57860/
http://dx.doi.org/10.11113/jt.v73.4406
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.57860
record_format eprints
spelling my.utm.578602022-04-07T04:44:40Z http://eprints.utm.my/id/eprint/57860/ Application of draw wire sensor in the tracking control of an electro hydraulic actuator system Salleh, S. Rahmat, M. F. Othman, S. M. Abidin, H. Z. P Philology. Linguistics A draw wire sensor is considered as a contact measurement method. It is normally used to measure the speed and position of a system. A draw wire sensor is convenient especially when a low cost solution and a small sensor dimension are desired. The objective of this paper is to describe the application of draw wire sensor in control tracking of electro hydraulic actuator system. This research started with the modelling of electro hydraulic actuator system by using system identification approach. During the data taking process, an experiment is conducted using electro hydraulic actuator test bed. A draw wire sensor is attached to the load of electro hydraulic actuator system to measure the output displacement when the system is injected with the desired input signal. Draw wire sensor is measuring the output displacement in millimeters and then the signal is converted to voltage reading regarding to the given input signal. The input and output signal is collected and is used in system identification technique to obtain the best mathematical model that can represent the electro hydraulic actuator system. Once a model is obtained, a Self Tuning Controller (STC) with Generalize Minimum Variance Control (GMVC) strategy is designed to control the tracking performance of the electro hydraulic actuator system. The designed controller is tested in simulation and experiment mode. Then, the output result from both modes is compared. The results show that the output performance from both modes are almost similar. Thus, this research had shown that a draw wire sensor has a significant role in capturing an accurate output data from electro hydraulic actuator system even with or without the controller. Penerbit UTM Press 2015 Article PeerReviewed Salleh, S. and Rahmat, M. F. and Othman, S. M. and Abidin, H. Z. (2015) Application of draw wire sensor in the tracking control of an electro hydraulic actuator system. Jurnal Teknologi, 73 (6). pp. 51-57. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v73.4406 DOI: 10.11113/jt.v73.4406
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic P Philology. Linguistics
spellingShingle P Philology. Linguistics
Salleh, S.
Rahmat, M. F.
Othman, S. M.
Abidin, H. Z.
Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
description A draw wire sensor is considered as a contact measurement method. It is normally used to measure the speed and position of a system. A draw wire sensor is convenient especially when a low cost solution and a small sensor dimension are desired. The objective of this paper is to describe the application of draw wire sensor in control tracking of electro hydraulic actuator system. This research started with the modelling of electro hydraulic actuator system by using system identification approach. During the data taking process, an experiment is conducted using electro hydraulic actuator test bed. A draw wire sensor is attached to the load of electro hydraulic actuator system to measure the output displacement when the system is injected with the desired input signal. Draw wire sensor is measuring the output displacement in millimeters and then the signal is converted to voltage reading regarding to the given input signal. The input and output signal is collected and is used in system identification technique to obtain the best mathematical model that can represent the electro hydraulic actuator system. Once a model is obtained, a Self Tuning Controller (STC) with Generalize Minimum Variance Control (GMVC) strategy is designed to control the tracking performance of the electro hydraulic actuator system. The designed controller is tested in simulation and experiment mode. Then, the output result from both modes is compared. The results show that the output performance from both modes are almost similar. Thus, this research had shown that a draw wire sensor has a significant role in capturing an accurate output data from electro hydraulic actuator system even with or without the controller.
format Article
author Salleh, S.
Rahmat, M. F.
Othman, S. M.
Abidin, H. Z.
author_facet Salleh, S.
Rahmat, M. F.
Othman, S. M.
Abidin, H. Z.
author_sort Salleh, S.
title Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
title_short Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
title_full Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
title_fullStr Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
title_full_unstemmed Application of draw wire sensor in the tracking control of an electro hydraulic actuator system
title_sort application of draw wire sensor in the tracking control of an electro hydraulic actuator system
publisher Penerbit UTM Press
publishDate 2015
url http://eprints.utm.my/id/eprint/57860/
http://dx.doi.org/10.11113/jt.v73.4406
_version_ 1729703220470611968
score 13.160551