Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System

This paper focuses on the parameter characterization of phenomenological modelling for commercially available Festo Fluidic Muscle Actuator. Phenomenological model consists of a spring element, nonlinear damping element and a contractile force element which arranged in parallel. The dynamic model wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Sakthi Velu, Vasanthan, Chong, Shin Horng, Tan, Ming Hui, Md Ghazaly, Mariam
Format: Article
Language:English
Published: Science And Engineering Research Support Society (SERSC) 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/21168/2/%5B2016IJCA%5D%20Phenomenological%20Modeling%20and%20Classic%20Control%20of%20a%20Pneumatic%20Muscle%20Actuator%20System.pdf
http://eprints.utem.edu.my/id/eprint/21168/
http://www.sersc.org/journals/IJCA/vol9_no4/30.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.21168
record_format eprints
spelling my.utem.eprints.211682021-07-13T23:16:15Z http://eprints.utem.edu.my/id/eprint/21168/ Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System Sakthi Velu, Vasanthan Chong, Shin Horng Tan, Ming Hui Md Ghazaly, Mariam T Technology (General) TJ Mechanical engineering and machinery This paper focuses on the parameter characterization of phenomenological modelling for commercially available Festo Fluidic Muscle Actuator. Phenomenological model consists of a spring element, nonlinear damping element and a contractile force element which arranged in parallel. The dynamic model was tested on the experimental setup which allows precise and accurate contraction due to the supply of pressure (P) to the PMA. The open loop data were collected for static load study and contraction study at several constant pressures. Only the contraction experiment was focused in this study by excluding the relaxation phase of the experiment. The result obtained shows that at constant pressure, the muscle actuator behaves like a spring and a nonlinear damping element. The contractile force coefficient element is the corresponding force generated by the muscle during contraction in longitudinal direction. Since, pressure is the main driving element in PMA system, all the coefficient value has a pressure dependent relationship. The model and parameters obtained from the study were further validated by predicting the contraction of the muscle system via simulation and experimental. Then, a classical PID control system was designed and validated in point-to-point positioning motion experimentally. Finally, a brief conclusion of the pneumatic muscle actuator experimental setup and dynamic system modeling is made. Science And Engineering Research Support Society (SERSC) 2016 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/21168/2/%5B2016IJCA%5D%20Phenomenological%20Modeling%20and%20Classic%20Control%20of%20a%20Pneumatic%20Muscle%20Actuator%20System.pdf Sakthi Velu, Vasanthan and Chong, Shin Horng and Tan, Ming Hui and Md Ghazaly, Mariam (2016) Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System. International Journal Of Control And Automation, 9 (4). pp. 301-312. ISSN 2005-4297 http://www.sersc.org/journals/IJCA/vol9_no4/30.pdf 10.14257/ijca.2016.9.4.30
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Sakthi Velu, Vasanthan
Chong, Shin Horng
Tan, Ming Hui
Md Ghazaly, Mariam
Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
description This paper focuses on the parameter characterization of phenomenological modelling for commercially available Festo Fluidic Muscle Actuator. Phenomenological model consists of a spring element, nonlinear damping element and a contractile force element which arranged in parallel. The dynamic model was tested on the experimental setup which allows precise and accurate contraction due to the supply of pressure (P) to the PMA. The open loop data were collected for static load study and contraction study at several constant pressures. Only the contraction experiment was focused in this study by excluding the relaxation phase of the experiment. The result obtained shows that at constant pressure, the muscle actuator behaves like a spring and a nonlinear damping element. The contractile force coefficient element is the corresponding force generated by the muscle during contraction in longitudinal direction. Since, pressure is the main driving element in PMA system, all the coefficient value has a pressure dependent relationship. The model and parameters obtained from the study were further validated by predicting the contraction of the muscle system via simulation and experimental. Then, a classical PID control system was designed and validated in point-to-point positioning motion experimentally. Finally, a brief conclusion of the pneumatic muscle actuator experimental setup and dynamic system modeling is made.
format Article
author Sakthi Velu, Vasanthan
Chong, Shin Horng
Tan, Ming Hui
Md Ghazaly, Mariam
author_facet Sakthi Velu, Vasanthan
Chong, Shin Horng
Tan, Ming Hui
Md Ghazaly, Mariam
author_sort Sakthi Velu, Vasanthan
title Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
title_short Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
title_full Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
title_fullStr Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
title_full_unstemmed Phenomenological Modeling And Classical Control Of A Pneumatic Muscle Actuator System
title_sort phenomenological modeling and classical control of a pneumatic muscle actuator system
publisher Science And Engineering Research Support Society (SERSC)
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/21168/2/%5B2016IJCA%5D%20Phenomenological%20Modeling%20and%20Classic%20Control%20of%20a%20Pneumatic%20Muscle%20Actuator%20System.pdf
http://eprints.utem.edu.my/id/eprint/21168/
http://www.sersc.org/journals/IJCA/vol9_no4/30.pdf
_version_ 1706960968053948416
score 13.160551