Failure investigation of a primary superheater tube
This paper presents the root cause failure investigation of P3T3 boiler tube of Unit 5 Stesen Janaelektrik Sultan Salahuddin Abdul Aziz (SJSSAA) Kapar. As Unit 5 requires running at all the time, any disruption of operation because of failure would cause the lose in revenue and potential disruption...
Saved in:
Main Authors: | Rahman M.M., Zuhairi M.H.A. |
---|---|
Other Authors: | 55328831100 |
Format: | Article |
Published: |
Microscopy Society of Malaysia
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
High operating steam pressure and localized overheating of a primary superheater tube
by: Ahmad J., et al.
Published: (2023) -
Root cause failure analysis of a division wall superheater tube of a coal-fired power station
by: Rahman M.M., et al.
Published: (2023) -
Failure analysis on a primary superheater tube of a power plant
by: Purbolaksono J., et al.
Published: (2023) -
Failure investigation on deformed superheater tubes
by: Othman H., et al.
Published: (2023) -
Development of optimized maintenance scheduling model for coal-fired power plant boiler
by: Noor Fazreen Binti Ahmad Fuzi, Ms.