Failure analysis on a primary superheater tube of a power plant

In this paper failure analysis on the SA213-T12 superheater tube by visual inspection, in situ measurements of hardness and finite element analyses is presented. A primary superheater tube has failed with a wide open burst after running at around 28,194 h. Heavy clinkers were found to almost entirel...

Full description

Saved in:
Bibliographic Details
Main Authors: Purbolaksono J., Ahmad J., Beng L.C., Rashid A.Z., Khinani A., Ali A.A.
Other Authors: 8621252500
Format: Article
Published: 2023
Subjects:
Tags: Add Tag