Isolation of GSH from Baker Yeast by Ultrasonic method

The purpose of this study was to determine the effect of operating parameters such as the yeast concentration, processing temperature and isolation time on the isolation of GSH using Ultrasonic method. The disrupted cells solution was centrifuged at 12,000 rpm for 20 min and the GSH content in the s...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed Salleh, Mohamad Ramlan, Jamal, Parveen, Salleh, Rohani, Hasim, Haslinda
Format: Article
Language:English
Published: Asian Network for Scientific Information 2004
Subjects:
Online Access:http://irep.iium.edu.my/9914/1/1741-1744.pdf
http://irep.iium.edu.my/9914/
http://scialert.net/abstract/?doi=pjbs.2004.1741.1744
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.9914
record_format dspace
spelling my.iium.irep.99142013-07-19T08:04:39Z http://irep.iium.edu.my/9914/ Isolation of GSH from Baker Yeast by Ultrasonic method Mohamed Salleh, Mohamad Ramlan Jamal, Parveen Salleh, Rohani Hasim, Haslinda TA164 Bioengineering TP248.13 Biotechnology The purpose of this study was to determine the effect of operating parameters such as the yeast concentration, processing temperature and isolation time on the isolation of GSH using Ultrasonic method. The disrupted cells solution was centrifuged at 12,000 rpm for 20 min and the GSH content in the supernatant was analyzed by taking the OD value of the solution using Spectrophotometer at 412 nm. To study the effect of yeast concentration, yeast solution with the concentration of 3, 6, 9 and 12 wt.% was disrupted at their original temperature for 15 sec. The result shows that the optimum value of yeast concentration is 6 wt.% where 12.93 μmol mL-1 GSH was isolated. To study the effect of processing temperature, Ultrasonic process of the 6 wt.% yeast solution was done at various values of temperature such as 19, 22, 25, 28, 30 and 40�C for 15 sec. The results indicated that, the optimum GSH isolation temperature is 22�C with the isolation of 13.53 μmol mL-1 GSH. Then, to study the effect of isolation time, the Ultrasonic process of sample with the concentration of 6 wt.% was done at 22�C for 15, 30, 45 and 60 sec. The result indicated that the optimum isolation time for the Ultrasonic process is 15 sec. Asian Network for Scientific Information 2004 Article REM application/pdf en http://irep.iium.edu.my/9914/1/1741-1744.pdf Mohamed Salleh, Mohamad Ramlan and Jamal, Parveen and Salleh, Rohani and Hasim, Haslinda (2004) Isolation of GSH from Baker Yeast by Ultrasonic method. Pakistan Journal of Biological Sciences, 7 (10). pp. 1741-1744. ISSN 1028-8880 http://scialert.net/abstract/?doi=pjbs.2004.1741.1744 10.3923/pjbs.2004.1741.1744
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TA164 Bioengineering
TP248.13 Biotechnology
spellingShingle TA164 Bioengineering
TP248.13 Biotechnology
Mohamed Salleh, Mohamad Ramlan
Jamal, Parveen
Salleh, Rohani
Hasim, Haslinda
Isolation of GSH from Baker Yeast by Ultrasonic method
description The purpose of this study was to determine the effect of operating parameters such as the yeast concentration, processing temperature and isolation time on the isolation of GSH using Ultrasonic method. The disrupted cells solution was centrifuged at 12,000 rpm for 20 min and the GSH content in the supernatant was analyzed by taking the OD value of the solution using Spectrophotometer at 412 nm. To study the effect of yeast concentration, yeast solution with the concentration of 3, 6, 9 and 12 wt.% was disrupted at their original temperature for 15 sec. The result shows that the optimum value of yeast concentration is 6 wt.% where 12.93 μmol mL-1 GSH was isolated. To study the effect of processing temperature, Ultrasonic process of the 6 wt.% yeast solution was done at various values of temperature such as 19, 22, 25, 28, 30 and 40�C for 15 sec. The results indicated that, the optimum GSH isolation temperature is 22�C with the isolation of 13.53 μmol mL-1 GSH. Then, to study the effect of isolation time, the Ultrasonic process of sample with the concentration of 6 wt.% was done at 22�C for 15, 30, 45 and 60 sec. The result indicated that the optimum isolation time for the Ultrasonic process is 15 sec.
format Article
author Mohamed Salleh, Mohamad Ramlan
Jamal, Parveen
Salleh, Rohani
Hasim, Haslinda
author_facet Mohamed Salleh, Mohamad Ramlan
Jamal, Parveen
Salleh, Rohani
Hasim, Haslinda
author_sort Mohamed Salleh, Mohamad Ramlan
title Isolation of GSH from Baker Yeast by Ultrasonic method
title_short Isolation of GSH from Baker Yeast by Ultrasonic method
title_full Isolation of GSH from Baker Yeast by Ultrasonic method
title_fullStr Isolation of GSH from Baker Yeast by Ultrasonic method
title_full_unstemmed Isolation of GSH from Baker Yeast by Ultrasonic method
title_sort isolation of gsh from baker yeast by ultrasonic method
publisher Asian Network for Scientific Information
publishDate 2004
url http://irep.iium.edu.my/9914/1/1741-1744.pdf
http://irep.iium.edu.my/9914/
http://scialert.net/abstract/?doi=pjbs.2004.1741.1744
_version_ 1643606319409659904