A review on surface tension measurements by optical method for medical application
Surface tension is a surface characteristic that is related to the forces of molecules residing at the interface. The presence of surface active substance in biological or body fluids which adsorb at interface influences the norm surface tension value. Such the changes indicate valuable signs in the...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Sains Islam Malaysia
2019
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/88209/1/GanesanKrishnan2019_AReviewonSurfaceTensionMeasurementsbyOptical.pdf http://eprints.utm.my/id/eprint/88209/ https://oarep.usim.edu.my/jspui/handle/123456789/5347 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.88209 |
---|---|
record_format |
eprints |
spelling |
my.utm.882092021-02-09T01:34:54Z http://eprints.utm.my/id/eprint/88209/ A review on surface tension measurements by optical method for medical application Mohamad Azlan Gan, Nur Najihah Gan Mohd Taib, Nur Athirah Krishnan, Ganesan Dasuki, Karsono Ahmad Q Science (General) Surface tension is a surface characteristic that is related to the forces of molecules residing at the interface. The presence of surface active substance in biological or body fluids which adsorb at interface influences the norm surface tension value. Such the changes indicate valuable signs in the medical field, particularly in pathological states. The conventional surface tension measurements suffered several flaws including lack of dynamic control and required a direct contact with the samples. The optical method seems to be attractive and useful in the surface phenomena owing to non-contact capabilities, non-destructive procedures and required a finite sample volume. In this paper, various optical techniques for surface tension measurement are reviewed and the potential applications regarding the surface tension through the meniscus formation are well discussed. This paper finds the simplicity and credibility of the optical method offers a good opportunity in fields such as medical and diagnostic analysis for monitoring applications. Universiti Sains Islam Malaysia 2019 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/88209/1/GanesanKrishnan2019_AReviewonSurfaceTensionMeasurementsbyOptical.pdf Mohamad Azlan Gan, Nur Najihah Gan and Mohd Taib, Nur Athirah and Krishnan, Ganesan and Dasuki, Karsono Ahmad (2019) A review on surface tension measurements by optical method for medical application. Malaysian Journal of Science, Health & Technology, 4 (1). pp. 1-6. ISSN 2601-0003 https://oarep.usim.edu.my/jspui/handle/123456789/5347 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
Q Science (General) |
spellingShingle |
Q Science (General) Mohamad Azlan Gan, Nur Najihah Gan Mohd Taib, Nur Athirah Krishnan, Ganesan Dasuki, Karsono Ahmad A review on surface tension measurements by optical method for medical application |
description |
Surface tension is a surface characteristic that is related to the forces of molecules residing at the interface. The presence of surface active substance in biological or body fluids which adsorb at interface influences the norm surface tension value. Such the changes indicate valuable signs in the medical field, particularly in pathological states. The conventional surface tension measurements suffered several flaws including lack of dynamic control and required a direct contact with the samples. The optical method seems to be attractive and useful in the surface phenomena owing to non-contact capabilities, non-destructive procedures and required a finite sample volume. In this paper, various optical techniques for surface tension measurement are reviewed and the potential applications regarding the surface tension through the meniscus formation are well discussed. This paper finds the simplicity and credibility of the optical method offers a good opportunity in fields such as medical and diagnostic analysis for monitoring applications. |
format |
Article |
author |
Mohamad Azlan Gan, Nur Najihah Gan Mohd Taib, Nur Athirah Krishnan, Ganesan Dasuki, Karsono Ahmad |
author_facet |
Mohamad Azlan Gan, Nur Najihah Gan Mohd Taib, Nur Athirah Krishnan, Ganesan Dasuki, Karsono Ahmad |
author_sort |
Mohamad Azlan Gan, Nur Najihah Gan |
title |
A review on surface tension measurements by optical method for medical application |
title_short |
A review on surface tension measurements by optical method for medical application |
title_full |
A review on surface tension measurements by optical method for medical application |
title_fullStr |
A review on surface tension measurements by optical method for medical application |
title_full_unstemmed |
A review on surface tension measurements by optical method for medical application |
title_sort |
review on surface tension measurements by optical method for medical application |
publisher |
Universiti Sains Islam Malaysia |
publishDate |
2019 |
url |
http://eprints.utm.my/id/eprint/88209/1/GanesanKrishnan2019_AReviewonSurfaceTensionMeasurementsbyOptical.pdf http://eprints.utm.my/id/eprint/88209/ https://oarep.usim.edu.my/jspui/handle/123456789/5347 |
_version_ |
1691733078777528320 |
score |
13.214268 |