A flexible optical sensor for microalbuminuria spectroscopy

A flexible optical sensor unit was developed for the detection of albumin level in human urine. It consists of polydimethylsiloxane thinfilm with the microscopic glass as the substrate. A gradual increase of albumin level may indicate signs of health problem such as diabetes, hypertension, and endot...

Full description

Saved in:
Bibliographic Details
Main Authors: Isaak, Suhaila, Yusof, Yusmeeraz, Mohd. Yusof, Khairunnisa, Kwan, Khoo Ming
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/86169/1/SuhailaIsaak2018_AFlexibleOpticalSensorforMicroalbuminuriaSpectroscopy.pdf
http://eprints.utm.my/id/eprint/86169/
http://dx.doi.org/10.11591/ijeecs.v10.i2.pp521-527
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.86169
record_format eprints
spelling my.utm.861692020-08-30T09:05:01Z http://eprints.utm.my/id/eprint/86169/ A flexible optical sensor for microalbuminuria spectroscopy Isaak, Suhaila Yusof, Yusmeeraz Mohd. Yusof, Khairunnisa Kwan, Khoo Ming TK Electrical engineering. Electronics Nuclear engineering A flexible optical sensor unit was developed for the detection of albumin level in human urine. It consists of polydimethylsiloxane thinfilm with the microscopic glass as the substrate. A gradual increase of albumin level may indicate signs of health problem such as diabetes, hypertension, and endothelial dysfunction. The experimental results showed there are a spectral shift and an increase in absorbed light increase in intensity of light with sodium urate at different concentration as a substitute of urine sample. The transmittance and reflection of PDMS was determined in the 400–1400 nm wavelength range using halogen-detrium as the excitation light source to predict the sensor sensitivity based on the Beer–Lambert law. The results exhibited that the light intensity increases as the concentration of the sodium urate increases. This performance of prototype sensor ignites an alternative for albumin detection using flexible structure. Institute of Advanced Engineering and Science 2018-05 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/86169/1/SuhailaIsaak2018_AFlexibleOpticalSensorforMicroalbuminuriaSpectroscopy.pdf Isaak, Suhaila and Yusof, Yusmeeraz and Mohd. Yusof, Khairunnisa and Kwan, Khoo Ming (2018) A flexible optical sensor for microalbuminuria spectroscopy. Indonesian Journal of Electrical Engineering and Computer Science, 10 (2). pp. 521-527. ISSN 2502-4752 http://dx.doi.org/10.11591/ijeecs.v10.i2.pp521-527
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Isaak, Suhaila
Yusof, Yusmeeraz
Mohd. Yusof, Khairunnisa
Kwan, Khoo Ming
A flexible optical sensor for microalbuminuria spectroscopy
description A flexible optical sensor unit was developed for the detection of albumin level in human urine. It consists of polydimethylsiloxane thinfilm with the microscopic glass as the substrate. A gradual increase of albumin level may indicate signs of health problem such as diabetes, hypertension, and endothelial dysfunction. The experimental results showed there are a spectral shift and an increase in absorbed light increase in intensity of light with sodium urate at different concentration as a substitute of urine sample. The transmittance and reflection of PDMS was determined in the 400–1400 nm wavelength range using halogen-detrium as the excitation light source to predict the sensor sensitivity based on the Beer–Lambert law. The results exhibited that the light intensity increases as the concentration of the sodium urate increases. This performance of prototype sensor ignites an alternative for albumin detection using flexible structure.
format Article
author Isaak, Suhaila
Yusof, Yusmeeraz
Mohd. Yusof, Khairunnisa
Kwan, Khoo Ming
author_facet Isaak, Suhaila
Yusof, Yusmeeraz
Mohd. Yusof, Khairunnisa
Kwan, Khoo Ming
author_sort Isaak, Suhaila
title A flexible optical sensor for microalbuminuria spectroscopy
title_short A flexible optical sensor for microalbuminuria spectroscopy
title_full A flexible optical sensor for microalbuminuria spectroscopy
title_fullStr A flexible optical sensor for microalbuminuria spectroscopy
title_full_unstemmed A flexible optical sensor for microalbuminuria spectroscopy
title_sort flexible optical sensor for microalbuminuria spectroscopy
publisher Institute of Advanced Engineering and Science
publishDate 2018
url http://eprints.utm.my/id/eprint/86169/1/SuhailaIsaak2018_AFlexibleOpticalSensorforMicroalbuminuriaSpectroscopy.pdf
http://eprints.utm.my/id/eprint/86169/
http://dx.doi.org/10.11591/ijeecs.v10.i2.pp521-527
_version_ 1677781140447952896