Real-time implementation of feed rate active force control of a syringe fluid dispenser

For precise application, it is imperative to provide accurate and stable performance. The feed flow rate of a syringe fluid dispensing system is regulated through a Proportional-Integral-Derivative (PID) and Active Force Control (AFC) control scheme that was actuated using a DC servo motor consideri...

Full description

Saved in:
Bibliographic Details
Main Authors: Sharif, S. K. B., Mailah, M.
Format: Article
Published: Penerbit UTM Press 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/76704/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021177109&doi=10.11113%2fjt.v79.10527&partnerID=40&md5=7b036ecf767f2280ef717550eea3898f
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.76704
record_format eprints
spelling my.utm.767042018-04-30T13:52:38Z http://eprints.utm.my/id/eprint/76704/ Real-time implementation of feed rate active force control of a syringe fluid dispenser Sharif, S. K. B. Mailah, M. TJ Mechanical engineering and machinery For precise application, it is imperative to provide accurate and stable performance. The feed flow rate of a syringe fluid dispensing system is regulated through a Proportional-Integral-Derivative (PID) and Active Force Control (AFC) control scheme that was actuated using a DC servo motor considering a real-time implementation. The focus of this study is to control the speed of a DC motor by implementing an AFC strategy in rejecting the disturbance in the system. The AFC is implemented by cascading its control loop with the outer PID controller loop to form a two degree-of-freedom (DOF) controller. The performance of the proposed PID with AFC control scheme was investigated considering both the theoretical simulation and experimental works. The simulation was performed in MATLAB/Simulink computing platform while the real-time experimentation was done by utilising the Arduino MEGA 2560 microcontroller with MATLAB/Simulink driver for the data acquisition, interface and control implementation. The results implies the robustness of the AFC-based system in controlling the feed flow rate of the fluid in the dispenser. The best performance is obtained for 100% AFC with the disturbance due to vibration almost completely compensated via the proposed scheme in comparison to the PID counterpart. Penerbit UTM Press 2017 Article PeerReviewed Sharif, S. K. B. and Mailah, M. (2017) Real-time implementation of feed rate active force control of a syringe fluid dispenser. Jurnal Teknologi, 79 (5). pp. 117-123. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021177109&doi=10.11113%2fjt.v79.10527&partnerID=40&md5=7b036ecf767f2280ef717550eea3898f DOI:10.11113/jt.v79.10527
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Sharif, S. K. B.
Mailah, M.
Real-time implementation of feed rate active force control of a syringe fluid dispenser
description For precise application, it is imperative to provide accurate and stable performance. The feed flow rate of a syringe fluid dispensing system is regulated through a Proportional-Integral-Derivative (PID) and Active Force Control (AFC) control scheme that was actuated using a DC servo motor considering a real-time implementation. The focus of this study is to control the speed of a DC motor by implementing an AFC strategy in rejecting the disturbance in the system. The AFC is implemented by cascading its control loop with the outer PID controller loop to form a two degree-of-freedom (DOF) controller. The performance of the proposed PID with AFC control scheme was investigated considering both the theoretical simulation and experimental works. The simulation was performed in MATLAB/Simulink computing platform while the real-time experimentation was done by utilising the Arduino MEGA 2560 microcontroller with MATLAB/Simulink driver for the data acquisition, interface and control implementation. The results implies the robustness of the AFC-based system in controlling the feed flow rate of the fluid in the dispenser. The best performance is obtained for 100% AFC with the disturbance due to vibration almost completely compensated via the proposed scheme in comparison to the PID counterpart.
format Article
author Sharif, S. K. B.
Mailah, M.
author_facet Sharif, S. K. B.
Mailah, M.
author_sort Sharif, S. K. B.
title Real-time implementation of feed rate active force control of a syringe fluid dispenser
title_short Real-time implementation of feed rate active force control of a syringe fluid dispenser
title_full Real-time implementation of feed rate active force control of a syringe fluid dispenser
title_fullStr Real-time implementation of feed rate active force control of a syringe fluid dispenser
title_full_unstemmed Real-time implementation of feed rate active force control of a syringe fluid dispenser
title_sort real-time implementation of feed rate active force control of a syringe fluid dispenser
publisher Penerbit UTM Press
publishDate 2017
url http://eprints.utm.my/id/eprint/76704/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021177109&doi=10.11113%2fjt.v79.10527&partnerID=40&md5=7b036ecf767f2280ef717550eea3898f