Empirical modelling of activated sludge process via system identification
Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf http://eprints.utm.my/id/eprint/71183/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.71183 |
---|---|
record_format |
eprints |
spelling |
my.utm.711832017-11-15T04:15:16Z http://eprints.utm.my/id/eprint/71183/ Empirical modelling of activated sludge process via system identification Norzain, N. A. Sahlan, S. Ab. Halim, F. Abdul Wahab, N. TK Electrical engineering. Electronics Nuclear engineering Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model with best fits of higher than 80 and the order of less than 10 is selected. For modelling purposes, data obtained is stimulated and modelled using System Identification technique which employ linear model ARX. For model reduction purposes, the high order model is reduced using model order reduction (MOR) of a combination of Singular Perturbation Approximation (SPA) and Frequency Domain Gramian based Model Reduction (FDIG) method. From the modelling results obtained, the ARX model with best fit of 85.11 is selected. Meanwhile, for the MOR FD-SPA technique, a 9th order model is selected with 2.5 x 10-2 reduction error between frequencies 0.05 rad/s and 1.4 rad/s. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf Norzain, N. A. and Sahlan, S. and Ab. Halim, F. and Abdul Wahab, N. (2016) Empirical modelling of activated sludge process via system identification. Jurnal Teknologi, 78 (7-4). pp. 155-162. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Norzain, N. A. Sahlan, S. Ab. Halim, F. Abdul Wahab, N. Empirical modelling of activated sludge process via system identification |
description |
Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model with best fits of higher than 80 and the order of less than 10 is selected. For modelling purposes, data obtained is stimulated and modelled using System Identification technique which employ linear model ARX. For model reduction purposes, the high order model is reduced using model order reduction (MOR) of a combination of Singular Perturbation Approximation (SPA) and Frequency Domain Gramian based Model Reduction (FDIG) method. From the modelling results obtained, the ARX model with best fit of 85.11 is selected. Meanwhile, for the MOR FD-SPA technique, a 9th order model is selected with 2.5 x 10-2 reduction error between frequencies 0.05 rad/s and 1.4 rad/s. |
format |
Article |
author |
Norzain, N. A. Sahlan, S. Ab. Halim, F. Abdul Wahab, N. |
author_facet |
Norzain, N. A. Sahlan, S. Ab. Halim, F. Abdul Wahab, N. |
author_sort |
Norzain, N. A. |
title |
Empirical modelling of activated sludge process via system identification |
title_short |
Empirical modelling of activated sludge process via system identification |
title_full |
Empirical modelling of activated sludge process via system identification |
title_fullStr |
Empirical modelling of activated sludge process via system identification |
title_full_unstemmed |
Empirical modelling of activated sludge process via system identification |
title_sort |
empirical modelling of activated sludge process via system identification |
publisher |
Penerbit UTM Press |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf http://eprints.utm.my/id/eprint/71183/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0 |
_version_ |
1643656128026902528 |
score |
13.211869 |