Empirical modelling of activated sludge process via system identification

Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model...

Full description

Saved in:
Bibliographic Details
Main Authors: Norzain, N. A., Sahlan, S., Ab. Halim, F., Abdul Wahab, N.
Format: Article
Language:English
Published: Penerbit UTM Press 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf
http://eprints.utm.my/id/eprint/71183/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.71183
record_format eprints
spelling my.utm.711832017-11-15T04:15:16Z http://eprints.utm.my/id/eprint/71183/ Empirical modelling of activated sludge process via system identification Norzain, N. A. Sahlan, S. Ab. Halim, F. Abdul Wahab, N. TK Electrical engineering. Electronics Nuclear engineering Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model with best fits of higher than 80 and the order of less than 10 is selected. For modelling purposes, data obtained is stimulated and modelled using System Identification technique which employ linear model ARX. For model reduction purposes, the high order model is reduced using model order reduction (MOR) of a combination of Singular Perturbation Approximation (SPA) and Frequency Domain Gramian based Model Reduction (FDIG) method. From the modelling results obtained, the ARX model with best fit of 85.11 is selected. Meanwhile, for the MOR FD-SPA technique, a 9th order model is selected with 2.5 x 10-2 reduction error between frequencies 0.05 rad/s and 1.4 rad/s. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf Norzain, N. A. and Sahlan, S. and Ab. Halim, F. and Abdul Wahab, N. (2016) Empirical modelling of activated sludge process via system identification. Jurnal Teknologi, 78 (7-4). pp. 155-162. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Norzain, N. A.
Sahlan, S.
Ab. Halim, F.
Abdul Wahab, N.
Empirical modelling of activated sludge process via system identification
description Activated sludge process is an important stage in Wastewater Treatment Plant (WWTP). In this study, model of the activated sludge process from Bunus Regional Sewage Treatment Plant Kuala Lumpur, Malaysia is developed. This paper focuses on modelling and model reduction of the WWTP system. The model with best fits of higher than 80 and the order of less than 10 is selected. For modelling purposes, data obtained is stimulated and modelled using System Identification technique which employ linear model ARX. For model reduction purposes, the high order model is reduced using model order reduction (MOR) of a combination of Singular Perturbation Approximation (SPA) and Frequency Domain Gramian based Model Reduction (FDIG) method. From the modelling results obtained, the ARX model with best fit of 85.11 is selected. Meanwhile, for the MOR FD-SPA technique, a 9th order model is selected with 2.5 x 10-2 reduction error between frequencies 0.05 rad/s and 1.4 rad/s.
format Article
author Norzain, N. A.
Sahlan, S.
Ab. Halim, F.
Abdul Wahab, N.
author_facet Norzain, N. A.
Sahlan, S.
Ab. Halim, F.
Abdul Wahab, N.
author_sort Norzain, N. A.
title Empirical modelling of activated sludge process via system identification
title_short Empirical modelling of activated sludge process via system identification
title_full Empirical modelling of activated sludge process via system identification
title_fullStr Empirical modelling of activated sludge process via system identification
title_full_unstemmed Empirical modelling of activated sludge process via system identification
title_sort empirical modelling of activated sludge process via system identification
publisher Penerbit UTM Press
publishDate 2016
url http://eprints.utm.my/id/eprint/71183/1/NorulAshikinNorzain2016_EmpiricalModellingofActivatedSludgeProcess.pdf
http://eprints.utm.my/id/eprint/71183/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979690504&doi=10.11113%2fjt.v78.9435&partnerID=40&md5=ee2963f0c1ef5dae3303ab595bd5a6f0
_version_ 1643656128026902528
score 13.211869