Results on frequency weighted model reduction techniques of activated sludge process

In this paper, a 90th order activated sludge process system is explored. From the original high order system, a disturbance between 1rad/s to 10rad/s are observed, hence frequency weighted model reduction techniques (FWMRT) are applied with a low pass filter of break frequency 0.5rad/s. Three well-k...

Full description

Saved in:
Bibliographic Details
Main Authors: Sahlan, S., Wahab, N. A., Darus, I. Z. M.
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51283/
http://dx.doi.org/10.1109/UKSim.2013.137
Tags: Add Tag