Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis

Conventional technique such as liquid-liquid extraction (LLE) is widely used in the analysis of Cu(II) ions from water samples. However, LLE is time consuming, tedious, and consume lots of high purity organic solvents. Solid phase extraction (SPE) is an interesting alternative to LLE but it is pro...

Full description

Saved in:
Bibliographic Details
Main Authors: Yunos, Muhammad Arif Azhar, Wan Ibrahim, Wan Aini, Abd. Wahib, Siti Munirah
Format: Article
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/66870/1/MuhammadArifAzharYunosa2016_Copper%28II%29iondeterminationinwatersamples.pdf
http://eprints.utm.my/id/eprint/66870/
http://eproceedings.chemistry.utm.my/index.php/FYP/article/view/51
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.66870
record_format eprints
spelling my.utm.668702017-11-14T06:23:13Z http://eprints.utm.my/id/eprint/66870/ Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis Yunos, Muhammad Arif Azhar Wan Ibrahim, Wan Aini Abd. Wahib, Siti Munirah Q Science Conventional technique such as liquid-liquid extraction (LLE) is widely used in the analysis of Cu(II) ions from water samples. However, LLE is time consuming, tedious, and consume lots of high purity organic solvents. Solid phase extraction (SPE) is an interesting alternative to LLE but it is prone to channelling and is rather expensive. A greener technique such as magnetic solid phase extraction (MSPE) avoids the use of column cartridge and overcome channelling problem. MSPE using magnetite-calcium alginate (Fe3O4-CaAlg) as sorbent is proposed for the extraction of Cu(II) ion from tap and lake water samples and analysis performed using flame atomic absorption spectrometry (FAAS). Characterization of the synthesised sorbent was performed using Fourier transform infrared spectroscopy and scanning electron microscope. The optimum conditions for Fe3O4-CaAlg MSPE of Cu(II) were achieved at a sample solution of pH 6 with 100 mL sample volume and the existence of interfering ions (Na+, K+, Mg2+, and Cl-) was found not to affect the extraction efficiency of the sorbent for Cu( II) ion significantly at the concentrations tested. Other MSPE parameters used were 10 min extraction time, 50 mg sorbent, 10 mL of 0.1 M HNO3 as desorption solvent and 5 min desorption time (sonication assisted). The calibration graph was linear from 20 - 600 ppb with good coefficient of determination (R2 = 0.9998). The LOD (3SD/slope) and LOQ (10SD/slope) of Cu(II) using Fe3O4-CaAlg MSPE with FAAS were in 6.75 and 22.5 ppb, respectively. The LOD achieved with the Fe3O4-CaAlg MSPE with FAAS is applicable to the determination of Cu(II) in real water samples (tap water and UTM lake water). Good relative recoveries and precision were achieved with this proposed method. The Fe3O4-CaAlg has great potential as an alternative sorbent for Cu(II) determination from water samples using the greener MSPE method. 2016-01-12 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/66870/1/MuhammadArifAzharYunosa2016_Copper%28II%29iondeterminationinwatersamples.pdf Yunos, Muhammad Arif Azhar and Wan Ibrahim, Wan Aini and Abd. Wahib, Siti Munirah (2016) Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis. Eproceeding Chemistry, 1 (1). pp. 58-62. ISSN 2550-1453 http://eproceedings.chemistry.utm.my/index.php/FYP/article/view/51
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic Q Science
spellingShingle Q Science
Yunos, Muhammad Arif Azhar
Wan Ibrahim, Wan Aini
Abd. Wahib, Siti Munirah
Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
description Conventional technique such as liquid-liquid extraction (LLE) is widely used in the analysis of Cu(II) ions from water samples. However, LLE is time consuming, tedious, and consume lots of high purity organic solvents. Solid phase extraction (SPE) is an interesting alternative to LLE but it is prone to channelling and is rather expensive. A greener technique such as magnetic solid phase extraction (MSPE) avoids the use of column cartridge and overcome channelling problem. MSPE using magnetite-calcium alginate (Fe3O4-CaAlg) as sorbent is proposed for the extraction of Cu(II) ion from tap and lake water samples and analysis performed using flame atomic absorption spectrometry (FAAS). Characterization of the synthesised sorbent was performed using Fourier transform infrared spectroscopy and scanning electron microscope. The optimum conditions for Fe3O4-CaAlg MSPE of Cu(II) were achieved at a sample solution of pH 6 with 100 mL sample volume and the existence of interfering ions (Na+, K+, Mg2+, and Cl-) was found not to affect the extraction efficiency of the sorbent for Cu( II) ion significantly at the concentrations tested. Other MSPE parameters used were 10 min extraction time, 50 mg sorbent, 10 mL of 0.1 M HNO3 as desorption solvent and 5 min desorption time (sonication assisted). The calibration graph was linear from 20 - 600 ppb with good coefficient of determination (R2 = 0.9998). The LOD (3SD/slope) and LOQ (10SD/slope) of Cu(II) using Fe3O4-CaAlg MSPE with FAAS were in 6.75 and 22.5 ppb, respectively. The LOD achieved with the Fe3O4-CaAlg MSPE with FAAS is applicable to the determination of Cu(II) in real water samples (tap water and UTM lake water). Good relative recoveries and precision were achieved with this proposed method. The Fe3O4-CaAlg has great potential as an alternative sorbent for Cu(II) determination from water samples using the greener MSPE method.
format Article
author Yunos, Muhammad Arif Azhar
Wan Ibrahim, Wan Aini
Abd. Wahib, Siti Munirah
author_facet Yunos, Muhammad Arif Azhar
Wan Ibrahim, Wan Aini
Abd. Wahib, Siti Munirah
author_sort Yunos, Muhammad Arif Azhar
title Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
title_short Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
title_full Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
title_fullStr Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
title_full_unstemmed Copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
title_sort copper(ii)ion determination in water samples using magnetite-calcium alginate sorbent and flame atomic absorption spectrometry analysis
publishDate 2016
url http://eprints.utm.my/id/eprint/66870/1/MuhammadArifAzharYunosa2016_Copper%28II%29iondeterminationinwatersamples.pdf
http://eprints.utm.my/id/eprint/66870/
http://eproceedings.chemistry.utm.my/index.php/FYP/article/view/51
_version_ 1643655852553404416
score 13.188404