An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application

The wideband operation of multi-port reflectometer may lead to inaccurate reflection coefficient measurement caused by the overlapped phase characteristics of the used calibration standards. Therefore, a calibration procedure implementing Least Mean Square (LMS) is proposed to offer accurate operati...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Yob, Rashidah, Seman, Norhudah
Format: Article
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/57731/
http://dx.doi.org/10.11113/jt.v73.4256
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.57731
record_format eprints
spelling my.utm.577312017-11-01T04:16:54Z http://eprints.utm.my/id/eprint/57731/ An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application Che Yob, Rashidah Seman, Norhudah T Technology (General) TK Electrical engineering. Electronics Nuclear engineering The wideband operation of multi-port reflectometer may lead to inaccurate reflection coefficient measurement caused by the overlapped phase characteristics of the used calibration standards. Therefore, a calibration procedure implementing Least Mean Square (LMS) is proposed to offer accurate operation of wideband multi-port reflectometer from 1 to 6 GHz. Its well wideband performance is verified by attenuators of 3, 6 and 10 dB that assessed as the device under tests (DUTs). The proposed LMS contains a learning rate, m and updated weight coefficient, W(k+1) to eliminate error and achieve the corrected reflection coefficient of DUT Penerbit UTM Press 2015-02 Article PeerReviewed Che Yob, Rashidah and Seman, Norhudah (2015) An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application. Jurnal Teknologi, 73 (3). pp. 119-125. ISSN 2180–3722 http://dx.doi.org/10.11113/jt.v73.4256 DOI:10.11113/jt.v73.4256
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Che Yob, Rashidah
Seman, Norhudah
An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
description The wideband operation of multi-port reflectometer may lead to inaccurate reflection coefficient measurement caused by the overlapped phase characteristics of the used calibration standards. Therefore, a calibration procedure implementing Least Mean Square (LMS) is proposed to offer accurate operation of wideband multi-port reflectometer from 1 to 6 GHz. Its well wideband performance is verified by attenuators of 3, 6 and 10 dB that assessed as the device under tests (DUTs). The proposed LMS contains a learning rate, m and updated weight coefficient, W(k+1) to eliminate error and achieve the corrected reflection coefficient of DUT
format Article
author Che Yob, Rashidah
Seman, Norhudah
author_facet Che Yob, Rashidah
Seman, Norhudah
author_sort Che Yob, Rashidah
title An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
title_short An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
title_full An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
title_fullStr An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
title_full_unstemmed An accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
title_sort accurate operation of wideband multi-port reflectometer with new calibration method implementing least mean square for microwave imaging application
publisher Penerbit UTM Press
publishDate 2015
url http://eprints.utm.my/id/eprint/57731/
http://dx.doi.org/10.11113/jt.v73.4256
_version_ 1643654064504832000