Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application

In this study, PCL microsphere has been synthesised using the double emulsion technique and a freeze dry technique. Bovine Serum Albumin (BSA) was added as a model protein and Hydroxyapatite (HA) to enhance osteoconductivity properties of the microsphere. Poly (caprolactone) (PCL)-based microspheres...

Full description

Saved in:
Bibliographic Details
Main Authors: Rashid, Mad Jin, Sultana, Naznin, Salehhuddin, Hamdan
Format: Article
Published: Trans Tech Publications, Switzerland 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/52846/
https://dx.doi.org/10.4028/www.scientific.net/AMR.1030-1032.82
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.52846
record_format eprints
spelling my.utm.528462018-07-04T11:52:21Z http://eprints.utm.my/id/eprint/52846/ Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application Rashid, Mad Jin Sultana, Naznin Salehhuddin, Hamdan QA76 Computer software In this study, PCL microsphere has been synthesised using the double emulsion technique and a freeze dry technique. Bovine Serum Albumin (BSA) was added as a model protein and Hydroxyapatite (HA) to enhance osteoconductivity properties of the microsphere. Poly (caprolactone) (PCL)-based microspheres were synthesized and characterized. Microspheres were produced with 5%, 10%, and 15% (w/v) PCL solution (30mL) by dissolving different amounts of PCL in dichloromethane (DCM). Microspheres produced from 5% (w/v) PCL concentration had an average diameter of 100 – 120 μm. Bovine serum albumin (BSA) (0.04% w/v) and 10% w/w of HA powder were added into the microspheres produced from 5% (w/v) PCL concentration. The microsphere was then characterized using different techniques and in vitro release study of BSA was conducted. Prepared microsphere showed good potential for bone tissue engineering. Trans Tech Publications, Switzerland 2014 Article PeerReviewed Rashid, Mad Jin and Sultana, Naznin and Salehhuddin, Hamdan (2014) Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application. Advanced Materials Research, 1030-1 . pp. 82-85. ISSN 1022-6680 https://dx.doi.org/10.4028/www.scientific.net/AMR.1030-1032.82 DOI: 10.4028/www.scientific.net/AMR.1030-1032.82
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QA76 Computer software
spellingShingle QA76 Computer software
Rashid, Mad Jin
Sultana, Naznin
Salehhuddin, Hamdan
Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
description In this study, PCL microsphere has been synthesised using the double emulsion technique and a freeze dry technique. Bovine Serum Albumin (BSA) was added as a model protein and Hydroxyapatite (HA) to enhance osteoconductivity properties of the microsphere. Poly (caprolactone) (PCL)-based microspheres were synthesized and characterized. Microspheres were produced with 5%, 10%, and 15% (w/v) PCL solution (30mL) by dissolving different amounts of PCL in dichloromethane (DCM). Microspheres produced from 5% (w/v) PCL concentration had an average diameter of 100 – 120 μm. Bovine serum albumin (BSA) (0.04% w/v) and 10% w/w of HA powder were added into the microspheres produced from 5% (w/v) PCL concentration. The microsphere was then characterized using different techniques and in vitro release study of BSA was conducted. Prepared microsphere showed good potential for bone tissue engineering.
format Article
author Rashid, Mad Jin
Sultana, Naznin
Salehhuddin, Hamdan
author_facet Rashid, Mad Jin
Sultana, Naznin
Salehhuddin, Hamdan
author_sort Rashid, Mad Jin
title Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
title_short Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
title_full Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
title_fullStr Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
title_full_unstemmed Fabrication of BSA loaded poly (Caprolactone) (PCL)/ hydroxyapatite (HA) composite microsphere for tissue engineering application
title_sort fabrication of bsa loaded poly (caprolactone) (pcl)/ hydroxyapatite (ha) composite microsphere for tissue engineering application
publisher Trans Tech Publications, Switzerland
publishDate 2014
url http://eprints.utm.my/id/eprint/52846/
https://dx.doi.org/10.4028/www.scientific.net/AMR.1030-1032.82
_version_ 1643653276847046656
score 13.18916