Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization

Miniaturized device is an approach by integrating the laboratory function into small platform. These miniaturized devices are equipped with sensors or actuators to perform sensing, sample preparation or analysis and is well known as lab-on-chip (LOC) since 1990. The conventional miniaturized device...

Full description

Saved in:
Bibliographic Details
Main Author: Azmi, Aizat
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/48808/1/AizatAzmiMFKE2015.pdf
http://eprints.utm.my/id/eprint/48808/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83700
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.48808
record_format eprints
spelling my.utm.488082020-06-24T02:41:52Z http://eprints.utm.my/id/eprint/48808/ Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization Azmi, Aizat TK Electrical engineering. Electronics Nuclear engineering Miniaturized device is an approach by integrating the laboratory function into small platform. These miniaturized devices are equipped with sensors or actuators to perform sensing, sample preparation or analysis and is well known as lab-on-chip (LOC) since 1990. The conventional miniaturized device available in the market normally provides single dimensional (1D) data at a time in most micro analysis processes. In order to obtain images from the device, cameras and microscopes are normally used. However, the size and tubing intact on the device make it difficult for cameras or optical devices to be placed within the reaction chamber to capture images that are related to the process. Processes such as cell detection and environmental analysis sometimes require two dimensional (2D) images in order to enhance the quality of analysis and data accuracy. Therefore, this research proposes to integrate tomography technique within the miniaturized device for capturing images within the device chamber in order to replace bulky optical equipment. Tomography system has been widely used in medical and industrial processes for image reconstruction. This research integrates Electrical Capacitance Tomography (ECT) system within a miniaturized device for visualization of stagnant samples via planar electrodes. This miniaturized planar tomography system consists of electrode array for the measurement of dielectric property changes within the chamber. This miniaturized device consists of 8-planar electrodes circulating the detection chamber where the dimension of each of the electrodes are 4 mm × 2 mm (length × width) printed on the circuit board. A home-made polydimenthylsiloxane chamber is fabricated and adhered on top of the electrodes to position the sample for electrical measurement and image reconstruction. Fan beam projection technique is utilized for data measurement from the miniaturized planar capacitive tomography system. The obtained data are processed using Linear Back Projection (LBP) algorithm via Matlab package for image reconstruction. Three samples: liquid-liquid, liquid-gas and liquid-solid are studied. Electrical measurement using fan beam projection is carried out and images of the samples are successfully reconstructed via LBP. Based on the obtained results, the error percentage for multiphase sample of water and air is 25% while 14.77% for solid sample of yeast and glucose. The obtained results show that the qualities of acquired images are highly depending on the voltage differences between each measurement. The amount of volume between the two materials affects the measured voltage differences. The nearer the samples to the planar electrode, the voltage differences observed are more significant. The reconstructed images using miniaturized planar capacitive tomography system for all the samples show good similarity to the camera captured images. 2015-03 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/48808/1/AizatAzmiMFKE2015.pdf Azmi, Aizat (2015) Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83700
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Azmi, Aizat
Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
description Miniaturized device is an approach by integrating the laboratory function into small platform. These miniaturized devices are equipped with sensors or actuators to perform sensing, sample preparation or analysis and is well known as lab-on-chip (LOC) since 1990. The conventional miniaturized device available in the market normally provides single dimensional (1D) data at a time in most micro analysis processes. In order to obtain images from the device, cameras and microscopes are normally used. However, the size and tubing intact on the device make it difficult for cameras or optical devices to be placed within the reaction chamber to capture images that are related to the process. Processes such as cell detection and environmental analysis sometimes require two dimensional (2D) images in order to enhance the quality of analysis and data accuracy. Therefore, this research proposes to integrate tomography technique within the miniaturized device for capturing images within the device chamber in order to replace bulky optical equipment. Tomography system has been widely used in medical and industrial processes for image reconstruction. This research integrates Electrical Capacitance Tomography (ECT) system within a miniaturized device for visualization of stagnant samples via planar electrodes. This miniaturized planar tomography system consists of electrode array for the measurement of dielectric property changes within the chamber. This miniaturized device consists of 8-planar electrodes circulating the detection chamber where the dimension of each of the electrodes are 4 mm × 2 mm (length × width) printed on the circuit board. A home-made polydimenthylsiloxane chamber is fabricated and adhered on top of the electrodes to position the sample for electrical measurement and image reconstruction. Fan beam projection technique is utilized for data measurement from the miniaturized planar capacitive tomography system. The obtained data are processed using Linear Back Projection (LBP) algorithm via Matlab package for image reconstruction. Three samples: liquid-liquid, liquid-gas and liquid-solid are studied. Electrical measurement using fan beam projection is carried out and images of the samples are successfully reconstructed via LBP. Based on the obtained results, the error percentage for multiphase sample of water and air is 25% while 14.77% for solid sample of yeast and glucose. The obtained results show that the qualities of acquired images are highly depending on the voltage differences between each measurement. The amount of volume between the two materials affects the measured voltage differences. The nearer the samples to the planar electrode, the voltage differences observed are more significant. The reconstructed images using miniaturized planar capacitive tomography system for all the samples show good similarity to the camera captured images.
format Thesis
author Azmi, Aizat
author_facet Azmi, Aizat
author_sort Azmi, Aizat
title Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
title_short Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
title_full Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
title_fullStr Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
title_full_unstemmed Miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
title_sort miniaturized planar capacitance tomography system using fan beam projection technique for stagnant samples visualization
publishDate 2015
url http://eprints.utm.my/id/eprint/48808/1/AizatAzmiMFKE2015.pdf
http://eprints.utm.my/id/eprint/48808/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83700
_version_ 1672610470362611712
score 13.160551