Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey

Result of PM10 (inhalable particulate matter) monitoring in Kuala Lumpur from September 1986 to Semptember 1088 are reported. Sampling was done using a size-selective high volume air sampler located on the roof-top of a four storey building at the existing UTM Air Quality Monitoring Station. On aver...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Yusoff, Mohd. Rashid
Format: Conference or Workshop Item
Language:English
Published: 1988
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3923/1/SKMBT_60007061915361.pdf
http://eprints.utm.my/id/eprint/3923/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.3923
record_format eprints
spelling my.utm.39232017-07-25T05:36:44Z http://eprints.utm.my/id/eprint/3923/ Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey Mohd. Yusoff, Mohd. Rashid TD Environmental technology. Sanitary engineering Result of PM10 (inhalable particulate matter) monitoring in Kuala Lumpur from September 1986 to Semptember 1088 are reported. Sampling was done using a size-selective high volume air sampler located on the roof-top of a four storey building at the existing UTM Air Quality Monitoring Station. On average, measurement of PM10 obtained was 50.8 ug/m³. This is closed to the annual value of USEPA standard of 50 ug/m³. Other pertinent findings are discussed in this paper. 1988-11-23 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/3923/1/SKMBT_60007061915361.pdf Mohd. Yusoff, Mohd. Rashid (1988) Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey. In: Symposium on Advances in tha Quality of the Malaysian Environment, 23 November 1988, Kuala lumpur.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Mohd. Yusoff, Mohd. Rashid
Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
description Result of PM10 (inhalable particulate matter) monitoring in Kuala Lumpur from September 1986 to Semptember 1088 are reported. Sampling was done using a size-selective high volume air sampler located on the roof-top of a four storey building at the existing UTM Air Quality Monitoring Station. On average, measurement of PM10 obtained was 50.8 ug/m³. This is closed to the annual value of USEPA standard of 50 ug/m³. Other pertinent findings are discussed in this paper.
format Conference or Workshop Item
author Mohd. Yusoff, Mohd. Rashid
author_facet Mohd. Yusoff, Mohd. Rashid
author_sort Mohd. Yusoff, Mohd. Rashid
title Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
title_short Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
title_full Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
title_fullStr Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
title_full_unstemmed Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey
title_sort summary of pm10 monitoring at one site of kuala lumpur : two years survey
publishDate 1988
url http://eprints.utm.my/id/eprint/3923/1/SKMBT_60007061915361.pdf
http://eprints.utm.my/id/eprint/3923/
_version_ 1643643921509646336
score 13.145126