Summary of PM10 monitoring at one site of Kuala Lumpur : Two years survey

Result of PM10 (inhalable particulate matter) monitoring in Kuala Lumpur from September 1986 to Semptember 1088 are reported. Sampling was done using a size-selective high volume air sampler located on the roof-top of a four storey building at the existing UTM Air Quality Monitoring Station. On aver...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Yusoff, Mohd. Rashid
Format: Conference or Workshop Item
Language:English
Published: 1988
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3923/1/SKMBT_60007061915361.pdf
http://eprints.utm.my/id/eprint/3923/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Result of PM10 (inhalable particulate matter) monitoring in Kuala Lumpur from September 1986 to Semptember 1088 are reported. Sampling was done using a size-selective high volume air sampler located on the roof-top of a four storey building at the existing UTM Air Quality Monitoring Station. On average, measurement of PM10 obtained was 50.8 ug/m³. This is closed to the annual value of USEPA standard of 50 ug/m³. Other pertinent findings are discussed in this paper.