Development of experimental-rig for human postural tremor behaviour

The purpose of this study is to investigate the human hand tremor behaviour in postural condition considering experimental works performed on actual human hand and a developed rig which was specifically designed to induce vibration in an intra vernacular training (IVT) hand-arm model. Two DC motors...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Zain, Mohd. Zarhamdy, As’arry, Azizan, Kazi, Suhail, Mailah, Musa, Hussein, Mohamed, Abdullah, Mohd. Yunus
Format: Article
Language:English
Published: Inderscience Publishers 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/37274/2/00000003%3Bjsessionid%3Dd3dm8sqe0s3.victoria
http://eprints.utm.my/id/eprint/37274/
http://dx.doi.org/10.1504/IJHFMS.2010.036795
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.37274
record_format eprints
spelling my.utm.372742017-02-11T00:41:42Z http://eprints.utm.my/id/eprint/37274/ Development of experimental-rig for human postural tremor behaviour Md. Zain, Mohd. Zarhamdy As’arry, Azizan Kazi, Suhail Mailah, Musa Hussein, Mohamed Abdullah, Mohd. Yunus TJ Mechanical engineering and machinery The purpose of this study is to investigate the human hand tremor behaviour in postural condition considering experimental works performed on actual human hand and a developed rig which was specifically designed to induce vibration in an intra vernacular training (IVT) hand-arm model. Two DC motors were used to spin unbalanced masses as the source of excitation to the model. Thus, this produces vibration along the hand-arm model to emulate the behaviour of postural tremor phenomenon. The quantitative assessment of tremor of the hand-arm model was mainly measured and recorded using a light-weight accelerometer and a displacement laser sensor. The accelerometer converts the physical movement into acceleration signals while the laser displacement sensor was used for precise measurement due to their high sensitivity in motion. The latter transducer was directly targeted at the palm of the hand, adjacent to the location of the accelerometer. The displacement and acceleration signals were then examined in both time and frequency domains. The results from the experiment and simulation study can be used for further analysis of human hand-arm tremor (of typically a PD patient) and the development of anti-human arm tremor device that can eventually suppress the tremor. Inderscience Publishers 2010-11 Article PeerReviewed text/html en http://eprints.utm.my/id/eprint/37274/2/00000003%3Bjsessionid%3Dd3dm8sqe0s3.victoria Md. Zain, Mohd. Zarhamdy and As’arry, Azizan and Kazi, Suhail and Mailah, Musa and Hussein, Mohamed and Abdullah, Mohd. Yunus (2010) Development of experimental-rig for human postural tremor behaviour. International Journal of Human Factors Modelling and Simulation, 1 (3). pp. 339-351. ISSN 1742-5549 http://dx.doi.org/10.1504/IJHFMS.2010.036795 DOI:10.1504/IJHFMS.2010.036795
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Md. Zain, Mohd. Zarhamdy
As’arry, Azizan
Kazi, Suhail
Mailah, Musa
Hussein, Mohamed
Abdullah, Mohd. Yunus
Development of experimental-rig for human postural tremor behaviour
description The purpose of this study is to investigate the human hand tremor behaviour in postural condition considering experimental works performed on actual human hand and a developed rig which was specifically designed to induce vibration in an intra vernacular training (IVT) hand-arm model. Two DC motors were used to spin unbalanced masses as the source of excitation to the model. Thus, this produces vibration along the hand-arm model to emulate the behaviour of postural tremor phenomenon. The quantitative assessment of tremor of the hand-arm model was mainly measured and recorded using a light-weight accelerometer and a displacement laser sensor. The accelerometer converts the physical movement into acceleration signals while the laser displacement sensor was used for precise measurement due to their high sensitivity in motion. The latter transducer was directly targeted at the palm of the hand, adjacent to the location of the accelerometer. The displacement and acceleration signals were then examined in both time and frequency domains. The results from the experiment and simulation study can be used for further analysis of human hand-arm tremor (of typically a PD patient) and the development of anti-human arm tremor device that can eventually suppress the tremor.
format Article
author Md. Zain, Mohd. Zarhamdy
As’arry, Azizan
Kazi, Suhail
Mailah, Musa
Hussein, Mohamed
Abdullah, Mohd. Yunus
author_facet Md. Zain, Mohd. Zarhamdy
As’arry, Azizan
Kazi, Suhail
Mailah, Musa
Hussein, Mohamed
Abdullah, Mohd. Yunus
author_sort Md. Zain, Mohd. Zarhamdy
title Development of experimental-rig for human postural tremor behaviour
title_short Development of experimental-rig for human postural tremor behaviour
title_full Development of experimental-rig for human postural tremor behaviour
title_fullStr Development of experimental-rig for human postural tremor behaviour
title_full_unstemmed Development of experimental-rig for human postural tremor behaviour
title_sort development of experimental-rig for human postural tremor behaviour
publisher Inderscience Publishers
publishDate 2010
url http://eprints.utm.my/id/eprint/37274/2/00000003%3Bjsessionid%3Dd3dm8sqe0s3.victoria
http://eprints.utm.my/id/eprint/37274/
http://dx.doi.org/10.1504/IJHFMS.2010.036795
_version_ 1643650108755017728
score 13.160551