QRS subtraction for atrial electrograms: flat, linear and spline interpolations
The main objective of this article is to implement and compare QRS subtraction techniques for intracardiac atrial electrograms based on using the surface ECG as a reference. A band-pass filter between 8 and 20 Hz followed by rectification, and then a low-pass filter at 6 Hz are used for QRS detectio...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
Springer-Verlag
2011
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/29385/ http://dx.doi.org/10.1007/s11517-011-0829-9 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.29385 |
---|---|
record_format |
eprints |
spelling |
my.utm.293852019-03-25T08:07:13Z http://eprints.utm.my/id/eprint/29385/ QRS subtraction for atrial electrograms: flat, linear and spline interpolations Ahmad, Anita Salinet Jr., J. L. Brown, P. Tuan, J. H. Stafford, P. Ng, G. Andre Schlindwein, F. S. TK Electrical engineering. Electronics Nuclear engineering The main objective of this article is to implement and compare QRS subtraction techniques for intracardiac atrial electrograms based on using the surface ECG as a reference. A band-pass filter between 8 and 20 Hz followed by rectification, and then a low-pass filter at 6 Hz are used for QRS detection. QRS subtraction was performed using three different approaches: flat, linear and spline interpolations. QRS subtraction affects the power of the signals but it normally does not affect the dominant frequency. The average power of the atrial electrograms after QRS subtraction is significantly reduced for frequencies above 10 Hz. Springer-Verlag 2011-11 Article PeerReviewed Ahmad, Anita and Salinet Jr., J. L. and Brown, P. and Tuan, J. H. and Stafford, P. and Ng, G. Andre and Schlindwein, F. S. (2011) QRS subtraction for atrial electrograms: flat, linear and spline interpolations. Medical and Biological Engineering and Computing, 49 (11). pp. 1321-1328. ISSN 0140-0118 http://dx.doi.org/10.1007/s11517-011-0829-9 DOI:10.1007/s11517-011-0829-9 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Ahmad, Anita Salinet Jr., J. L. Brown, P. Tuan, J. H. Stafford, P. Ng, G. Andre Schlindwein, F. S. QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
description |
The main objective of this article is to implement and compare QRS subtraction techniques for intracardiac atrial electrograms based on using the surface ECG as a reference. A band-pass filter between 8 and 20 Hz followed by rectification, and then a low-pass filter at 6 Hz are used for QRS detection. QRS subtraction was performed using three different approaches: flat, linear and spline interpolations. QRS subtraction affects the power of the signals but it normally does not affect the dominant frequency. The average power of the atrial electrograms after QRS subtraction is significantly reduced for frequencies above 10 Hz. |
format |
Article |
author |
Ahmad, Anita Salinet Jr., J. L. Brown, P. Tuan, J. H. Stafford, P. Ng, G. Andre Schlindwein, F. S. |
author_facet |
Ahmad, Anita Salinet Jr., J. L. Brown, P. Tuan, J. H. Stafford, P. Ng, G. Andre Schlindwein, F. S. |
author_sort |
Ahmad, Anita |
title |
QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
title_short |
QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
title_full |
QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
title_fullStr |
QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
title_full_unstemmed |
QRS subtraction for atrial electrograms: flat, linear and spline interpolations |
title_sort |
qrs subtraction for atrial electrograms: flat, linear and spline interpolations |
publisher |
Springer-Verlag |
publishDate |
2011 |
url |
http://eprints.utm.my/id/eprint/29385/ http://dx.doi.org/10.1007/s11517-011-0829-9 |
_version_ |
1643648288258260992 |
score |
13.209306 |