Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries
A capillary electrophoresis method using indirect UV detection has been applied to the determination of arsenate [As(V)], arsenite [As(III)], monomethylarsonic acid and dimethylarsinic acid. The arsenic species were successfully separated in a successive multiple ionic polymer layer coated capillary...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier BV
2009
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/14432/1/JafariahJaafar2009_FieldEnhancedSampleInjectionCE.pdf http://eprints.utm.my/id/eprint/14432/ http://dx.doi.org/10.1365/s10337-009-1063-6 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.14432 |
---|---|
record_format |
eprints |
spelling |
my.utm.144322017-02-07T07:56:38Z http://eprints.utm.my/id/eprint/14432/ Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries Jaafar, Jafariah Konishi, Kanami Terabe, Shigeru Ikegami, Tohru Tanaka, Nobuo QH301 Biology QH426 Genetics A capillary electrophoresis method using indirect UV detection has been applied to the determination of arsenate [As(V)], arsenite [As(III)], monomethylarsonic acid and dimethylarsinic acid. The arsenic species were successfully separated in a successive multiple ionic polymer layer coated capillary. On-line sample preconcentration of arsenic compounds were performed by employing field enhanced sample injection. A baseline separation was achieved in a basic background solution of 10 mM 2,6-pyridinedicarboxylic acid at pH 10.3. The precision of migration time was 1.2-2.4% RSD and peak height was 8.1-12.9% RSD. The limits of detection at a S/N ratio of 3 for the four arsenic compounds were found to be 20-70 ppb, which are comparable to other on-line preconcentration techniques. The enhancement factor was improved by 230-1,500-fold. Elsevier BV 2009 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/14432/1/JafariahJaafar2009_FieldEnhancedSampleInjectionCE.pdf Jaafar, Jafariah and Konishi, Kanami and Terabe, Shigeru and Ikegami, Tohru and Tanaka, Nobuo (2009) Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries. Chromatographia, 69 (11-12). pp. 1437-1441. ISSN 0009-5893 http://dx.doi.org/10.1365/s10337-009-1063-6 doi:10.1365/s10337-009-1063-6 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
QH301 Biology QH426 Genetics |
spellingShingle |
QH301 Biology QH426 Genetics Jaafar, Jafariah Konishi, Kanami Terabe, Shigeru Ikegami, Tohru Tanaka, Nobuo Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
description |
A capillary electrophoresis method using indirect UV detection has been applied to the determination of arsenate [As(V)], arsenite [As(III)], monomethylarsonic acid and dimethylarsinic acid. The arsenic species were successfully separated in a successive multiple ionic polymer layer coated capillary. On-line sample preconcentration of arsenic compounds were performed by employing field enhanced sample injection. A baseline separation was achieved in a basic background solution of 10 mM 2,6-pyridinedicarboxylic acid at pH 10.3. The precision of migration time was 1.2-2.4% RSD and peak height was 8.1-12.9% RSD. The limits of detection at a S/N ratio of 3 for the four arsenic compounds were found to be 20-70 ppb, which are comparable to other on-line preconcentration techniques. The enhancement factor was improved by 230-1,500-fold. |
format |
Article |
author |
Jaafar, Jafariah Konishi, Kanami Terabe, Shigeru Ikegami, Tohru Tanaka, Nobuo |
author_facet |
Jaafar, Jafariah Konishi, Kanami Terabe, Shigeru Ikegami, Tohru Tanaka, Nobuo |
author_sort |
Jaafar, Jafariah |
title |
Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
title_short |
Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
title_full |
Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
title_fullStr |
Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
title_full_unstemmed |
Field enhanced sample injection for the CE determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
title_sort |
field enhanced sample injection for the ce determination of arsenic compounds using successive multiple ionic polymer layer coated capillaries |
publisher |
Elsevier BV |
publishDate |
2009 |
url |
http://eprints.utm.my/id/eprint/14432/1/JafariahJaafar2009_FieldEnhancedSampleInjectionCE.pdf http://eprints.utm.my/id/eprint/14432/ http://dx.doi.org/10.1365/s10337-009-1063-6 |
_version_ |
1643646392861720576 |
score |
13.209306 |