Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model
The modelling of the supercapacitor (SC) plays an important role for the industrial application with many model representations such as electrical, chemical, and electrochemical models. Among one of those models are the equivalent circuit model which has been used to describe the real-time (charging...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science (IAES)
2021
|
Online Access: | http://psasir.upm.edu.my/id/eprint/97200/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/97200/ https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25379 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.upm.eprints.97200 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.972002022-09-13T05:05:41Z http://psasir.upm.edu.my/id/eprint/97200/ Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model Alsabari, Ali Mohsen Hassan, Mohd Khair Che Soh, Azura Abdul Rahman, Ribhan Zafira The modelling of the supercapacitor (SC) plays an important role for the industrial application with many model representations such as electrical, chemical, and electrochemical models. Among one of those models are the equivalent circuit model which has been used to describe the real-time (charging/discharging) operation characteristics of the SC. Apart of its mathematical complexity, the time-consuming experimentally is also a real challenge for obtaining the internal parameters values for the SC. Choices of test equipment with a structure design of experiment also play important criteria affect the accuracy of the model. This research emphasis on a structured of experimental design for SC modelling by using Neware battery tester. The experimental exercise to attain internal parameters of the SC are described and discussed in the paper. The findings were benchmarked with an empirical model of previous researchers. The terminal voltage of SC was validated via experiment with maximum relative error of 0.045%. The model successfully reproduce the SC dynamic behavior during the charge/discharge phase which indicates the proposed method and model accuracy. Institute of Advanced Engineering and Science (IAES) 2021 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/97200/1/ABSTRACT.pdf Alsabari, Ali Mohsen and Hassan, Mohd Khair and Che Soh, Azura and Abdul Rahman, Ribhan Zafira (2021) Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model. Indonesian Journal of Electrical Engineering and Computer Science, 23 (1). 63 - 74. ISSN 2502-4752; ESSN: 2502-4760 https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25379 10.11591/ijeecs.v23.i1.pp63-74 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
The modelling of the supercapacitor (SC) plays an important role for the industrial application with many model representations such as electrical, chemical, and electrochemical models. Among one of those models are the equivalent circuit model which has been used to describe the real-time (charging/discharging) operation characteristics of the SC. Apart of its mathematical complexity, the time-consuming experimentally is also a real challenge for obtaining the internal parameters values for the SC. Choices of test equipment with a structure design of experiment also play important criteria affect the accuracy of the model. This research emphasis on a structured of experimental design for SC modelling by using Neware battery tester. The experimental exercise to attain internal parameters of the SC are described and discussed in the paper. The findings were benchmarked with an empirical model of previous researchers. The terminal voltage of SC was validated via experiment with maximum relative error of 0.045%. The model successfully reproduce the SC dynamic behavior during the charge/discharge phase which indicates the proposed method and model accuracy. |
format |
Article |
author |
Alsabari, Ali Mohsen Hassan, Mohd Khair Che Soh, Azura Abdul Rahman, Ribhan Zafira |
spellingShingle |
Alsabari, Ali Mohsen Hassan, Mohd Khair Che Soh, Azura Abdul Rahman, Ribhan Zafira Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
author_facet |
Alsabari, Ali Mohsen Hassan, Mohd Khair Che Soh, Azura Abdul Rahman, Ribhan Zafira |
author_sort |
Alsabari, Ali Mohsen |
title |
Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
title_short |
Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
title_full |
Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
title_fullStr |
Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
title_full_unstemmed |
Experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
title_sort |
experimental design for an enhanced parametric modeling of supercapacitor equivalent circuit model |
publisher |
Institute of Advanced Engineering and Science (IAES) |
publishDate |
2021 |
url |
http://psasir.upm.edu.my/id/eprint/97200/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/97200/ https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25379 |
_version_ |
1744355311862415360 |
score |
13.214268 |