An electrochemical biosensor for the determination of Ganorderma boninense pathogen based on a novel modified gold nanocomposite film electrode

A sensitive approach for the determination of Ganoderma boninense DNA is reported based on an electrochemical affinity system using a modified gold sensor. Covalent attachment of probe DNA was achieved by attachment of the amine group to a carboxylic acid group of a 3,3’-dithiodipropionic acid monol...

Full description

Saved in:
Bibliographic Details
Main Authors: Dutse, Sabo Wada, Yusof, Nor Azah, Ahmad, Haslina, Hussein, Mohd Zobir, Zainal, Zulkarnain, Hushiarian, Roozbeh, Hajian, Reza
Format: Article
Language:English
Published: Taylor & Francis 2014
Online Access:http://psasir.upm.edu.my/id/eprint/36404/1/An%20electrochemical%20biosensor%20for%20the%20determination%20of%20Ganorderma%20boninense%20pathogen%20based%20on%20a%20novel%20modified%20gold%20nanocomposite%20film%20electrode.pdf
http://psasir.upm.edu.my/id/eprint/36404/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A sensitive approach for the determination of Ganoderma boninense DNA is reported based on an electrochemical affinity system using a modified gold sensor. Covalent attachment of probe DNA was achieved by attachment of the amine group to a carboxylic acid group of a 3,3’-dithiodipropionic acid monolayer on a nanocomposite film of gold nanoparticles bound to poly(3,4-ethylenedioxythiophen)–poly(styrenesulfonate) on a gold working electrode. The electrochemical detection of sequence-specific DNA of probe and target DNA hybridization was monitored using a new ruthenium complex [Ru(dppz) 2 (qtpy)Cl 2 ; dppz = dipyrido [3,2–a:2’,3’-c] phenazine; qtpy = 2,2’,-4,4”.4’4”’-quarterpyridyl redox marker. The potential was selected through the study of the electrochemical behavior of trisaminomethane-hydrochloride containing a ethylenediaminetetraacetic acid supporting electrolyte on the bare and modified gold electrode. The effect of the hybridization temperature and time were measured. The sensor demonstrated specific detection for the target over a concentration range of 1.0 × 10− 15 M to 1.0 × 10− 9 M with a detection limit of 1.59 × 10− 17 M. Control experiments verified the specificity of the biosensor in the presence of a single mismatched DNA sequence. This detection technology was shown to be effective in terms of sensitivity and selectivity of hybridization events and is a promising device for early detection of Ganoderma boninense and other pathogenic threat agents.