Failure investigation on deformed superheater tubes
Investigation is conducted following the discovery of significant deformations and the presence of cracks in the vicinity of welded joints at the superheater tubes of a heat recovery steam generator (HRSG) in a Malaysian Electricity Company's power plant. This study performs the finite element...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-30846 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-308462023-12-29T15:54:31Z Failure investigation on deformed superheater tubes Othman H. Purbolaksono J. Ahmad B. 25228759600 8621252500 36781813400 Deformation Failure analysis Finite element method Superheater tube Cell culture Correlation methods Electric power generation Electric power plants Finite element method Power plants Steam power plants Superheaters Tubes (components) Visual communication Waste heat Welded steel structures Welding Deformation Failure analysis Failure investigations Finite element Heat-recovery steam generator Malaysian Maximum stress Restriction condition Root causes Superheater tube Visual inspection Welded joints Superheater tubes Investigation is conducted following the discovery of significant deformations and the presence of cracks in the vicinity of welded joints at the superheater tubes of a heat recovery steam generator (HRSG) in a Malaysian Electricity Company's power plant. This study performs the finite element (FE) analyses in order to identify the possible root cause failure of the deformed superheater tubes using software package of MSC PATRAN/NASTRAN. The locations of maximum stress induced by the deformed tube are determined. The correlation between the maximum stress and allowable restriction condition is presented, and it shows good correlations with the findings obtained from the visual inspection on site. � 2008 Elsevier Ltd. All rights reserved. Final 2023-12-29T07:54:31Z 2023-12-29T07:54:31Z 2009 Article 10.1016/j.engfailanal.2008.05.023 2-s2.0-53849111203 https://www.scopus.com/inward/record.uri?eid=2-s2.0-53849111203&doi=10.1016%2fj.engfailanal.2008.05.023&partnerID=40&md5=461765f70e0b4b84f1f45673df032042 https://irepository.uniten.edu.my/handle/123456789/30846 16 1 329 339 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Deformation Failure analysis Finite element method Superheater tube Cell culture Correlation methods Electric power generation Electric power plants Finite element method Power plants Steam power plants Superheaters Tubes (components) Visual communication Waste heat Welded steel structures Welding Deformation Failure analysis Failure investigations Finite element Heat-recovery steam generator Malaysian Maximum stress Restriction condition Root causes Superheater tube Visual inspection Welded joints Superheater tubes |
spellingShingle |
Deformation Failure analysis Finite element method Superheater tube Cell culture Correlation methods Electric power generation Electric power plants Finite element method Power plants Steam power plants Superheaters Tubes (components) Visual communication Waste heat Welded steel structures Welding Deformation Failure analysis Failure investigations Finite element Heat-recovery steam generator Malaysian Maximum stress Restriction condition Root causes Superheater tube Visual inspection Welded joints Superheater tubes Othman H. Purbolaksono J. Ahmad B. Failure investigation on deformed superheater tubes |
description |
Investigation is conducted following the discovery of significant deformations and the presence of cracks in the vicinity of welded joints at the superheater tubes of a heat recovery steam generator (HRSG) in a Malaysian Electricity Company's power plant. This study performs the finite element (FE) analyses in order to identify the possible root cause failure of the deformed superheater tubes using software package of MSC PATRAN/NASTRAN. The locations of maximum stress induced by the deformed tube are determined. The correlation between the maximum stress and allowable restriction condition is presented, and it shows good correlations with the findings obtained from the visual inspection on site. � 2008 Elsevier Ltd. All rights reserved. |
author2 |
25228759600 |
author_facet |
25228759600 Othman H. Purbolaksono J. Ahmad B. |
format |
Article |
author |
Othman H. Purbolaksono J. Ahmad B. |
author_sort |
Othman H. |
title |
Failure investigation on deformed superheater tubes |
title_short |
Failure investigation on deformed superheater tubes |
title_full |
Failure investigation on deformed superheater tubes |
title_fullStr |
Failure investigation on deformed superheater tubes |
title_full_unstemmed |
Failure investigation on deformed superheater tubes |
title_sort |
failure investigation on deformed superheater tubes |
publishDate |
2023 |
_version_ |
1806428012754763776 |
score |
13.214268 |