Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver

This paper introduces a new method to repower the existing equipment of the AL-Hartha steam plant located in Basra, Iraq, using a molten salt cavity tubular solar central receiver (SCR). Cycle Tempo is used to simulate the existing natural gas-fuelled conventional steam power cycle with consideratio...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamel M.S., Abd Rahman A., Shamsuddin A.H.
Other Authors: 55541995800
Format: Article
Published: Springer Verlag 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-21972
record_format dspace
spelling my.uniten.dspace-219722023-05-16T10:46:23Z Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver Jamel M.S. Abd Rahman A. Shamsuddin A.H. 55541995800 36994910600 35779071900 This paper introduces a new method to repower the existing equipment of the AL-Hartha steam plant located in Basra, Iraq, using a molten salt cavity tubular solar central receiver (SCR). Cycle Tempo is used to simulate the existing natural gas-fuelled conventional steam power cycle with consideration of the heat and pressure losses. The heliostat field and the central receiver subsystems are coded using MATLAB. The model couples the heat balance with the temperature computation of the receiver walls for calculation and analysis of the thermal losses. The proposed modified codes are capable of calculating heat losses, evaluating the integrated power plant and satisfying a wide range of SCRs. The results are verified against plant data and previous works in the literature and good agreement is obtained. The results show the potential of using a molten salt cavity tubular SCR for low-range temperature feedwater preheating, as well as the optimum scheme for the integration of the existing plant with an SCR. It is observed that the maximum improvement for the existing AL-Hartha steam plant and the integrated molten salt cavity tubular SCR is obtained by substituting the bleed steam in all the high-pressure feed-water heaters. For this scheme, the obtained receiver energy efficiency reaches up to 94.1 % and the maximum reduction in instantaneous gas fuel consumption is about 10.1 % with a solar-electricity improvement of about 21.6 % over the design case. © Springer-Verlag Berlin Heidelberg 2014. Final 2023-05-16T02:46:23Z 2023-05-16T02:46:23Z 2014 Article 10.1007/s10098-014-0740-9 2-s2.0-84948072615 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84948072615&doi=10.1007%2fs10098-014-0740-9&partnerID=40&md5=8c990d3f1b3d9c49dee5c935fd39a3c7 https://irepository.uniten.edu.my/handle/123456789/21972 16 8 1661 1674 Springer Verlag Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description This paper introduces a new method to repower the existing equipment of the AL-Hartha steam plant located in Basra, Iraq, using a molten salt cavity tubular solar central receiver (SCR). Cycle Tempo is used to simulate the existing natural gas-fuelled conventional steam power cycle with consideration of the heat and pressure losses. The heliostat field and the central receiver subsystems are coded using MATLAB. The model couples the heat balance with the temperature computation of the receiver walls for calculation and analysis of the thermal losses. The proposed modified codes are capable of calculating heat losses, evaluating the integrated power plant and satisfying a wide range of SCRs. The results are verified against plant data and previous works in the literature and good agreement is obtained. The results show the potential of using a molten salt cavity tubular SCR for low-range temperature feedwater preheating, as well as the optimum scheme for the integration of the existing plant with an SCR. It is observed that the maximum improvement for the existing AL-Hartha steam plant and the integrated molten salt cavity tubular SCR is obtained by substituting the bleed steam in all the high-pressure feed-water heaters. For this scheme, the obtained receiver energy efficiency reaches up to 94.1 % and the maximum reduction in instantaneous gas fuel consumption is about 10.1 % with a solar-electricity improvement of about 21.6 % over the design case. © Springer-Verlag Berlin Heidelberg 2014.
author2 55541995800
author_facet 55541995800
Jamel M.S.
Abd Rahman A.
Shamsuddin A.H.
format Article
author Jamel M.S.
Abd Rahman A.
Shamsuddin A.H.
spellingShingle Jamel M.S.
Abd Rahman A.
Shamsuddin A.H.
Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
author_sort Jamel M.S.
title Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
title_short Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
title_full Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
title_fullStr Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
title_full_unstemmed Repowering of existing AL-Hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
title_sort repowering of existing al-hartha gas-fuelled conventional steam power plant with molten salt cavity tubular solar central receiver
publisher Springer Verlag
publishDate 2023
_version_ 1806424221055713280
score 13.214268