EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria
Ag-sheathed T1-1212 tapes with a nominal composition of (T1Cr)SrCaCuO were fabricated using the powder-in-tube (PIT) method. Two sets of samples were annealed in oxygen flow at 800C and 890C each for 30 minutes. Another set was annealed at 800C for 1 hour. The tapes showed transition temperature, T...
Saved in:
Main Author: | |
---|---|
Format: | text::Thesis |
Language: | English |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-20874 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-208742023-05-04T23:40:11Z EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria Rohaizah Binti Selamat Superconductor Superconductivity Ag-sheathed T1-1212 tapes with a nominal composition of (T1Cr)SrCaCuO were fabricated using the powder-in-tube (PIT) method. Two sets of samples were annealed in oxygen flow at 800C and 890C each for 30 minutes. Another set was annealed at 800C for 1 hour. The tapes showed transition temperature, T between 80K to 100K. 2023-05-03T15:29:45Z 2023-05-03T15:29:45Z 2000 Resource Types::text::Thesis https://irepository.uniten.edu.my/handle/123456789/20874 en application/pdf |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
topic |
Superconductor Superconductivity |
spellingShingle |
Superconductor Superconductivity Rohaizah Binti Selamat EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
description |
Ag-sheathed T1-1212 tapes with a nominal composition of (T1Cr)SrCaCuO were fabricated using the powder-in-tube (PIT) method. Two sets of samples were annealed in oxygen flow at 800C and 890C each for 30 minutes. Another set was annealed at 800C for 1 hour. The tapes showed transition temperature, T between 80K to 100K. |
format |
Resource Types::text::Thesis |
author |
Rohaizah Binti Selamat |
author_facet |
Rohaizah Binti Selamat |
author_sort |
Rohaizah Binti Selamat |
title |
EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
title_short |
EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
title_full |
EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
title_fullStr |
EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
title_full_unstemmed |
EPRB423 Project II Measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uV/cm criteria |
title_sort |
eprb423 project ii measurement of the transport critical current in thallium-1212 tapes at 77k using the 1uv/cm criteria |
publishDate |
2023 |
_version_ |
1806426534009896960 |
score |
13.235362 |