Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector

For a long time, the presence of histamine in foods related to food poisoning owing to inappropriate storage of food. Histamine is generally used as an indicator of food safety. This study used HPLC to analyze histamine which was very accurate yet time-consuming and used many organic solvents which...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad Abdurrahman, Munir, Khairiah Haji, Badri, Lee, Yook Heng, Nurul, Kusumawardani, Rizal, Fauzi
Format: Article
Language:English
Published: AIP Publishing 2022
Subjects:
Online Access:http://ir.unimas.my/id/eprint/43943/1/Determinatio.pdf
http://ir.unimas.my/id/eprint/43943/
https://pubs.aip.org/aip/acp/article-abstract/2493/1/030001/2827005/Determination-of-histamine-using-chemical-sensor?redirectedFrom=fulltext
https://doi.org/10.1063/5.0109921
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.43943
record_format eprints
spelling my.unimas.ir.439432023-12-29T07:35:23Z http://ir.unimas.my/id/eprint/43943/ Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector Muhammad Abdurrahman, Munir Khairiah Haji, Badri Lee, Yook Heng Nurul, Kusumawardani Rizal, Fauzi QD Chemistry For a long time, the presence of histamine in foods related to food poisoning owing to inappropriate storage of food. Histamine is generally used as an indicator of food safety. This study used HPLC to analyze histamine which was very accurate yet time-consuming and used many organic solvents which are not good for the environment. Therefore, the purpose of this work is to develop a non-enzymatic electrochemical technique to detect histamine using screen– printed polyurethane electrode (SPPE) in phosphate buffer solution (PBS) at pH 7.5, SPPE showed a very low oxidation potential of histamine at +0.31 V (vs. Ag/AgCl) avoiding perturbations from other amines such as cadaverine, putrescine and aniline. The developed method offered a satisfactory selectivity, detection limit at 0.17 µmol·L−1 and linear range at 10−4 – 1 mmol·L−1 for histamine detection. In addition, the proposed method was successfully applied to detect histamine with concentrations at 0.01 and 0.1 mmol·L−1 in fish mackerel and canned fish with recovery values ranging from 94 and 103%, respectively. Amperometric detection of histamine in fish samples using screen-printed polyurethane electrode was applied and compared with HPLC and presented high promise to be applied as an inexpensive and effective tool for food safety surveillance. AIP Publishing 2022-12-05 Article PeerReviewed text en http://ir.unimas.my/id/eprint/43943/1/Determinatio.pdf Muhammad Abdurrahman, Munir and Khairiah Haji, Badri and Lee, Yook Heng and Nurul, Kusumawardani and Rizal, Fauzi (2022) Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector. AIP Conference Proceedings, 2493 (1). pp. 1-9. ISSN 1551-7616 https://pubs.aip.org/aip/acp/article-abstract/2493/1/030001/2827005/Determination-of-histamine-using-chemical-sensor?redirectedFrom=fulltext https://doi.org/10.1063/5.0109921
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Muhammad Abdurrahman, Munir
Khairiah Haji, Badri
Lee, Yook Heng
Nurul, Kusumawardani
Rizal, Fauzi
Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
description For a long time, the presence of histamine in foods related to food poisoning owing to inappropriate storage of food. Histamine is generally used as an indicator of food safety. This study used HPLC to analyze histamine which was very accurate yet time-consuming and used many organic solvents which are not good for the environment. Therefore, the purpose of this work is to develop a non-enzymatic electrochemical technique to detect histamine using screen– printed polyurethane electrode (SPPE) in phosphate buffer solution (PBS) at pH 7.5, SPPE showed a very low oxidation potential of histamine at +0.31 V (vs. Ag/AgCl) avoiding perturbations from other amines such as cadaverine, putrescine and aniline. The developed method offered a satisfactory selectivity, detection limit at 0.17 µmol·L−1 and linear range at 10−4 – 1 mmol·L−1 for histamine detection. In addition, the proposed method was successfully applied to detect histamine with concentrations at 0.01 and 0.1 mmol·L−1 in fish mackerel and canned fish with recovery values ranging from 94 and 103%, respectively. Amperometric detection of histamine in fish samples using screen-printed polyurethane electrode was applied and compared with HPLC and presented high promise to be applied as an inexpensive and effective tool for food safety surveillance.
format Article
author Muhammad Abdurrahman, Munir
Khairiah Haji, Badri
Lee, Yook Heng
Nurul, Kusumawardani
Rizal, Fauzi
author_facet Muhammad Abdurrahman, Munir
Khairiah Haji, Badri
Lee, Yook Heng
Nurul, Kusumawardani
Rizal, Fauzi
author_sort Muhammad Abdurrahman, Munir
title Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
title_short Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
title_full Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
title_fullStr Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
title_full_unstemmed Determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (SPPE) compared to HPLC equipped fluorescence detector
title_sort determination of histamine using chemical sensor based on amperometric technique using screen-printed polyurethane electrode (sppe) compared to hplc equipped fluorescence detector
publisher AIP Publishing
publishDate 2022
url http://ir.unimas.my/id/eprint/43943/1/Determinatio.pdf
http://ir.unimas.my/id/eprint/43943/
https://pubs.aip.org/aip/acp/article-abstract/2493/1/030001/2827005/Determination-of-histamine-using-chemical-sensor?redirectedFrom=fulltext
https://doi.org/10.1063/5.0109921
_version_ 1787140556980224000
score 13.209306