Performance Investigation of R32 and R410a Refrigerants with Different Compressor Lubricants
The present study aims to investigate the effect of changing air conditioning refrigerants and compressor lubricants on system performance. Two types of refrigerants namely R410a and R32 paired with two different lubricants were investigated. A test rig consists of residential air conditioning with...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Springer Singapore
2023
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/41843/1/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor.pdf http://umpir.ump.edu.my/id/eprint/41843/2/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor%20Lubricants.pdf http://umpir.ump.edu.my/id/eprint/41843/ https://doi.org/10.1007/978-981-19-4425-3_23 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Internet
http://umpir.ump.edu.my/id/eprint/41843/1/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor.pdfhttp://umpir.ump.edu.my/id/eprint/41843/2/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor%20Lubricants.pdf