Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus

Radon-222 is naturally occurring radioactive gas where decay of Uranium-238 in soil, rock and groundwater. The harmful of radon can affect the human health and can cause lung cancer if expose to high level of radon concentration. Concern of this situations, this study to monitoring radon concentrati...

Full description

Saved in:
Bibliographic Details
Main Author: Abd Karim, Siti Fatimah
Format: Undergraduate Final Project Report
Published: 2016
Online Access:http://discol.umk.edu.my/id/eprint/6945/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.umk.eprints.6945
record_format eprints
spelling my.umk.eprints.69452022-05-23T08:50:13Z http://discol.umk.edu.my/id/eprint/6945/ Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus Abd Karim, Siti Fatimah Radon-222 is naturally occurring radioactive gas where decay of Uranium-238 in soil, rock and groundwater. The harmful of radon can affect the human health and can cause lung cancer if expose to high level of radon concentration. Concern of this situations, this study to monitoring radon concentration at different level of altitude and to study correlation between Rn-222 concentration, temperature, humidity and pressure in indoor areas of the building. Radon concentration was measured indoor using Radon Sentinel Model 1030 device in academic building UMK Jeli Campus. Lecture Room (BK 4) in the first floor and Lecture Room (BK 8) in the third floor of academic building UMK Jeli Campus were selected as the study areas. The duration of measurement radon concentration was completed in fifteen days for each lecture room. The radon concentration in BK 4 was found to have range of average value from 0.36 pCi/L to 0.73 pCi/L for fifteen consecutive days. Whereas, the radon concentration in BK 8 was found to have range of average value from 0.40 pCi/L to 0.93 pCi/L for fifteen consecutive days. Besides, the radon concentration is higher at BK 8 with height 14.4 meter than BK 4 with height 4.8 meter from the ground. From the correlation between Rn-222 concentration with pressure, temperature and humidity at BK 4, shows the negative correlation. While, the correlation between Rn-222 concentration with pressure, and humidity at BK 8, shown the positive correlation and correlation between Rn-222 with temperature at the BK 8 is negative correlation. 2016 Undergraduate Final Project Report NonPeerReviewed Abd Karim, Siti Fatimah (2016) Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus. Undergraduate Final Project Report thesis, Faculty of Earth Sciences. (Submitted)
institution Universiti Malaysia Kelantan
building Perpustakaan Universiti Malaysia Kelantan
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Kelantan
content_source UMK Institutional Repository
url_provider http://umkeprints.umk.edu.my/
description Radon-222 is naturally occurring radioactive gas where decay of Uranium-238 in soil, rock and groundwater. The harmful of radon can affect the human health and can cause lung cancer if expose to high level of radon concentration. Concern of this situations, this study to monitoring radon concentration at different level of altitude and to study correlation between Rn-222 concentration, temperature, humidity and pressure in indoor areas of the building. Radon concentration was measured indoor using Radon Sentinel Model 1030 device in academic building UMK Jeli Campus. Lecture Room (BK 4) in the first floor and Lecture Room (BK 8) in the third floor of academic building UMK Jeli Campus were selected as the study areas. The duration of measurement radon concentration was completed in fifteen days for each lecture room. The radon concentration in BK 4 was found to have range of average value from 0.36 pCi/L to 0.73 pCi/L for fifteen consecutive days. Whereas, the radon concentration in BK 8 was found to have range of average value from 0.40 pCi/L to 0.93 pCi/L for fifteen consecutive days. Besides, the radon concentration is higher at BK 8 with height 14.4 meter than BK 4 with height 4.8 meter from the ground. From the correlation between Rn-222 concentration with pressure, temperature and humidity at BK 4, shows the negative correlation. While, the correlation between Rn-222 concentration with pressure, and humidity at BK 8, shown the positive correlation and correlation between Rn-222 with temperature at the BK 8 is negative correlation.
format Undergraduate Final Project Report
author Abd Karim, Siti Fatimah
spellingShingle Abd Karim, Siti Fatimah
Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
author_facet Abd Karim, Siti Fatimah
author_sort Abd Karim, Siti Fatimah
title Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
title_short Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
title_full Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
title_fullStr Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
title_full_unstemmed Monitoring of Rn-222 Concentration in Relation to Temperature, Humidity and Pressure at Different Level of Altitude Academic Building of Universiti Malaysia Kelantan, Jeli Campus
title_sort monitoring of rn-222 concentration in relation to temperature, humidity and pressure at different level of altitude academic building of universiti malaysia kelantan, jeli campus
publishDate 2016
url http://discol.umk.edu.my/id/eprint/6945/
_version_ 1763303769882230784
score 13.211869