Balance and stability issues in lower extremity exoskeletons: A systematic review

The lower extremity exoskeletons (LEE) are used as an assistive device for disabled people, rehabilitation for paraplegic, and power augmentation for military or industrial workers. In all the applications of LEE, the dynamic and static balance, prevention of falling, ensuring controller stability a...

Full description

Saved in:
Bibliographic Details
Main Authors: Hamza, Mukhtar Fatihu, Raja Ghazilla, Raja Arif, Muhammad, Bashir Bala, Yap, Hwa Jen
Format: Article
Published: Elsevier 2020
Subjects:
Online Access:http://eprints.um.edu.my/36359/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.36359
record_format eprints
spelling my.um.eprints.363592023-11-29T14:54:52Z http://eprints.um.edu.my/36359/ Balance and stability issues in lower extremity exoskeletons: A systematic review Hamza, Mukhtar Fatihu Raja Ghazilla, Raja Arif Muhammad, Bashir Bala Yap, Hwa Jen T Technology (General) TJ Mechanical engineering and machinery The lower extremity exoskeletons (LEE) are used as an assistive device for disabled people, rehabilitation for paraplegic, and power augmentation for military or industrial workers. In all the applications of LEE, the dynamic and static balance, prevention of falling, ensuring controller stability and smooth human-exoskeleton interaction are of critical importance for the safety of LEE users. Although numerous studies have been conducted on the balance and stability issues in LEEs, there is yet to be a systematic review that provides a holistic viewpoint and highlights the current research challenges. This paper reviews the advances in the inclusion of falling recognition, balance recovery and stability assurance strategies in the design and application of LEEs. The current status of research on LEEs is presented. It has been found that Zero Moment Point (ZMP), Centre of Mass (CoM) and Extrapolated Center of mass (XCoM) ideas are mostly used for balancing and prevention of falling. In addition, Lyapunov stability criteria are the dominant methods for controller stability confirmation and smooth human-exoskeleton interaction. The challenges and future trend of this domain of research are discussed. Researchers can use this review as a basis to further develop methods for ensuring the safety of LEE's users. (c) 2020 Published by Elsevier B.V. on behalf of Nalecz Institute of Biocybernetics and Biomedical Engineering of the Polish Academy of Sciences. Elsevier 2020-10 Article PeerReviewed Hamza, Mukhtar Fatihu and Raja Ghazilla, Raja Arif and Muhammad, Bashir Bala and Yap, Hwa Jen (2020) Balance and stability issues in lower extremity exoskeletons: A systematic review. Biocybernetics and Biomedical Engineering, 40 (4). pp. 1666-1679. ISSN 0208-5216, DOI https://doi.org/10.1016/j.bbe.2020.09.004 <https://doi.org/10.1016/j.bbe.2020.09.004>. 10.1016/j.bbe.2020.09.004
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Hamza, Mukhtar Fatihu
Raja Ghazilla, Raja Arif
Muhammad, Bashir Bala
Yap, Hwa Jen
Balance and stability issues in lower extremity exoskeletons: A systematic review
description The lower extremity exoskeletons (LEE) are used as an assistive device for disabled people, rehabilitation for paraplegic, and power augmentation for military or industrial workers. In all the applications of LEE, the dynamic and static balance, prevention of falling, ensuring controller stability and smooth human-exoskeleton interaction are of critical importance for the safety of LEE users. Although numerous studies have been conducted on the balance and stability issues in LEEs, there is yet to be a systematic review that provides a holistic viewpoint and highlights the current research challenges. This paper reviews the advances in the inclusion of falling recognition, balance recovery and stability assurance strategies in the design and application of LEEs. The current status of research on LEEs is presented. It has been found that Zero Moment Point (ZMP), Centre of Mass (CoM) and Extrapolated Center of mass (XCoM) ideas are mostly used for balancing and prevention of falling. In addition, Lyapunov stability criteria are the dominant methods for controller stability confirmation and smooth human-exoskeleton interaction. The challenges and future trend of this domain of research are discussed. Researchers can use this review as a basis to further develop methods for ensuring the safety of LEE's users. (c) 2020 Published by Elsevier B.V. on behalf of Nalecz Institute of Biocybernetics and Biomedical Engineering of the Polish Academy of Sciences.
format Article
author Hamza, Mukhtar Fatihu
Raja Ghazilla, Raja Arif
Muhammad, Bashir Bala
Yap, Hwa Jen
author_facet Hamza, Mukhtar Fatihu
Raja Ghazilla, Raja Arif
Muhammad, Bashir Bala
Yap, Hwa Jen
author_sort Hamza, Mukhtar Fatihu
title Balance and stability issues in lower extremity exoskeletons: A systematic review
title_short Balance and stability issues in lower extremity exoskeletons: A systematic review
title_full Balance and stability issues in lower extremity exoskeletons: A systematic review
title_fullStr Balance and stability issues in lower extremity exoskeletons: A systematic review
title_full_unstemmed Balance and stability issues in lower extremity exoskeletons: A systematic review
title_sort balance and stability issues in lower extremity exoskeletons: a systematic review
publisher Elsevier
publishDate 2020
url http://eprints.um.edu.my/36359/
_version_ 1783945855390187520
score 13.159267