Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique

Three-dimensional (3D) knee angle measurement is one of the key measures in human gait analysis. Inertial sensor capable of measuring joint motion under unconstrained conditions is a practical tool for clinical evaluation and rehabilitation. An inertial measurement unit (IMU) consisting of accelerom...

Full description

Saved in:
Bibliographic Details
Main Authors: Tham, Lai Kuan, Abu Osman, Noor Azuan, Al Kouzbary, Mouaz, Aminian, Kamiar
Format: Article
Published: Institute of Electrical and Electronics Engineers 2021
Subjects:
Online Access:http://eprints.um.edu.my/26402/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.26402
record_format eprints
spelling my.um.eprints.264022022-02-25T07:56:11Z http://eprints.um.edu.my/26402/ Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique Tham, Lai Kuan Abu Osman, Noor Azuan Al Kouzbary, Mouaz Aminian, Kamiar TA Engineering (General). Civil engineering (General) Three-dimensional (3D) knee angle measurement is one of the key measures in human gait analysis. Inertial sensor capable of measuring joint motion under unconstrained conditions is a practical tool for clinical evaluation and rehabilitation. An inertial measurement unit (IMU) consisting of accelerometer and gyroscope allows orientation measurement in 3D with an additional sensor (i.e., magnetometer). However, ferromagnetic interference negatively affects the performance of magnetometer and thus reduces measurement accuracy. In this study, a technique based on nonlinear autoregressive neural network with exogenous inputs (NARX) is presented to measure 3D segmental orientation during gait without the use of magnetometer. With IMUs attached to the thigh and shank, 3D knee angles in long-distance treadmill walking were computed and validated against an optical motion analysis system as the gold standard. Pseudo-integrator (PI) was also compared to the reference system for benchmarking. The learning capability of NARX was further assessed with the comparison of complementary filter (CF) to the reference system. The proposed NARX model was shown to outperform PI with biases between -3.5 degrees and -0.2 degrees, and root mean square errors between 4.5 degrees and 2.5 degrees. Results demonstrated the capability of NARX in providing accurate estimates of 3D knee joint angle while avoiding interference as encountered in systems incorporating magnetometer, suggesting that NARX is feasible to computing long-term ambulatory measurements of body segment orientation and 3D joint angles. Institute of Electrical and Electronics Engineers 2021 Article PeerReviewed Tham, Lai Kuan and Abu Osman, Noor Azuan and Al Kouzbary, Mouaz and Aminian, Kamiar (2021) Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique. IEEE Access, 9. pp. 36559-36570. ISSN 2169-3536, DOI https://doi.org/10.1109/ACCESS.2021.3062978 <https://doi.org/10.1109/ACCESS.2021.3062978>. 10.1109/ACCESS.2021.3062978
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Tham, Lai Kuan
Abu Osman, Noor Azuan
Al Kouzbary, Mouaz
Aminian, Kamiar
Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
description Three-dimensional (3D) knee angle measurement is one of the key measures in human gait analysis. Inertial sensor capable of measuring joint motion under unconstrained conditions is a practical tool for clinical evaluation and rehabilitation. An inertial measurement unit (IMU) consisting of accelerometer and gyroscope allows orientation measurement in 3D with an additional sensor (i.e., magnetometer). However, ferromagnetic interference negatively affects the performance of magnetometer and thus reduces measurement accuracy. In this study, a technique based on nonlinear autoregressive neural network with exogenous inputs (NARX) is presented to measure 3D segmental orientation during gait without the use of magnetometer. With IMUs attached to the thigh and shank, 3D knee angles in long-distance treadmill walking were computed and validated against an optical motion analysis system as the gold standard. Pseudo-integrator (PI) was also compared to the reference system for benchmarking. The learning capability of NARX was further assessed with the comparison of complementary filter (CF) to the reference system. The proposed NARX model was shown to outperform PI with biases between -3.5 degrees and -0.2 degrees, and root mean square errors between 4.5 degrees and 2.5 degrees. Results demonstrated the capability of NARX in providing accurate estimates of 3D knee joint angle while avoiding interference as encountered in systems incorporating magnetometer, suggesting that NARX is feasible to computing long-term ambulatory measurements of body segment orientation and 3D joint angles.
format Article
author Tham, Lai Kuan
Abu Osman, Noor Azuan
Al Kouzbary, Mouaz
Aminian, Kamiar
author_facet Tham, Lai Kuan
Abu Osman, Noor Azuan
Al Kouzbary, Mouaz
Aminian, Kamiar
author_sort Tham, Lai Kuan
title Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
title_short Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
title_full Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
title_fullStr Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
title_full_unstemmed Biomechanical ambulatory assessment of 3D knee angle using novel inertial sensor-based technique
title_sort biomechanical ambulatory assessment of 3d knee angle using novel inertial sensor-based technique
publisher Institute of Electrical and Electronics Engineers
publishDate 2021
url http://eprints.um.edu.my/26402/
_version_ 1735409408004849664
score 13.18916