Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2015
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf http://eprints.um.edu.my/13886/ https://doi.org/10.1016/j.jtice.2014.09.013 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.13886 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.138862019-03-19T03:35:42Z http://eprints.um.edu.my/13886/ Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant Chew, C.M. Aroua, M.K. Hussain, Mohd Azlan Wan Ismail, W.M.Z. T Technology (General) TP Chemical technology Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using dead-end polyethersulfone UF membrane filtration system to produce up to 14 million litres a day of drinking water to a small township. Literature solutions are compared with the practised solutions and elucidated with the case study. Gaps between literature solutions which are mainly based on lab-scale research and industry practices are identified. Reducing this gap will have vast implication to improve the design and operation of industrial-scale UF treatment system. (C) 2014 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved. Elsevier 2015-01 Article PeerReviewed application/pdf en http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf Chew, C.M. and Aroua, M.K. and Hussain, Mohd Azlan and Wan Ismail, W.M.Z. (2015) Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant. Journal of the Taiwan Institute of Chemical Engineers, 46. pp. 132-139. ISSN 1876-1070 https://doi.org/10.1016/j.jtice.2014.09.013 doi:10.1016/j.jtice.2014.09.013 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
T Technology (General) TP Chemical technology |
spellingShingle |
T Technology (General) TP Chemical technology Chew, C.M. Aroua, M.K. Hussain, Mohd Azlan Wan Ismail, W.M.Z. Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
description |
Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using dead-end polyethersulfone UF membrane filtration system to produce up to 14 million litres a day of drinking water to a small township. Literature solutions are compared with the practised solutions and elucidated with the case study. Gaps between literature solutions which are mainly based on lab-scale research and industry practices are identified. Reducing this gap will have vast implication to improve the design and operation of industrial-scale UF treatment system. (C) 2014 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved. |
format |
Article |
author |
Chew, C.M. Aroua, M.K. Hussain, Mohd Azlan Wan Ismail, W.M.Z. |
author_facet |
Chew, C.M. Aroua, M.K. Hussain, Mohd Azlan Wan Ismail, W.M.Z. |
author_sort |
Chew, C.M. |
title |
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
title_short |
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
title_full |
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
title_fullStr |
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
title_full_unstemmed |
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
title_sort |
practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant |
publisher |
Elsevier |
publishDate |
2015 |
url |
http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf http://eprints.um.edu.my/13886/ https://doi.org/10.1016/j.jtice.2014.09.013 |
_version_ |
1643689676034277376 |
score |
13.160551 |