Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2015
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf http://eprints.um.edu.my/13886/ https://doi.org/10.1016/j.jtice.2014.09.013 |