A new parameterized architectural design for SENSE reconstruction
Reconfigurable hardware based architectures that could provide good quality image reconstruction for parallel Magnetic Resonance Imaging (MRI) within very less computation time are in high demand. Hardware platforms for specific reconstruction algorithms dramatically increase the power efficiency a...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/12967/1/A_New_Parameterized_Architectural.pdf http://eprints.um.edu.my/12967/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.12967 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.129672015-03-11T00:59:17Z http://eprints.um.edu.my/12967/ A new parameterized architectural design for SENSE reconstruction Siddiqui, M.F. Reza, A.W. Kanesan, J. Omer, H. TK Electrical engineering. Electronics Nuclear engineering Reconfigurable hardware based architectures that could provide good quality image reconstruction for parallel Magnetic Resonance Imaging (MRI) within very less computation time are in high demand. Hardware platforms for specific reconstruction algorithms dramatically increase the power efficiency and decrease the execution time. This research proposes a new parameterized architecture design for Sensitivity Encoding (SENSE) reconstruction. This architecture is also synthesized for Field Programmable Gate Array (FPGA). Complex multiplier, divider and complex matrix multiplier modules are designed to implement the algorithm. Furthermore, the variable data bus widths are used in the data path of the architecture, which leads to reduce the hardware cost and silicon area. Experimental results and comparisons prove the efficiency of the architecture. Moreover, in terms of computation time, the result shows that the proposed technique is 1000 times faster than the conventional MATLAB reconstruction, while maintaining the quality of the reconstructed image. The results indicate that this architectural design can prove to be a significant tool for SENSE reconstruction in MRI scanners. 2014-12 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/12967/1/A_New_Parameterized_Architectural.pdf Siddiqui, M.F. and Reza, A.W. and Kanesan, J. and Omer, H. (2014) A new parameterized architectural design for SENSE reconstruction. In: Proceedings of the 3rd International Conference on Computer Engineering & Mathematical Sciences (ICCEMS 2014), 04-05 Dec 2014, Langkawi, Malaysia. |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Siddiqui, M.F. Reza, A.W. Kanesan, J. Omer, H. A new parameterized architectural design for SENSE reconstruction |
description |
Reconfigurable hardware based architectures that could
provide good quality image reconstruction for parallel Magnetic Resonance Imaging (MRI) within very less computation time are in high demand. Hardware platforms for specific reconstruction algorithms dramatically increase the power efficiency and decrease the execution time. This research proposes a new parameterized architecture design for Sensitivity Encoding (SENSE) reconstruction. This architecture is also synthesized for Field Programmable Gate Array (FPGA). Complex multiplier, divider and complex matrix multiplier modules are designed to implement the algorithm. Furthermore, the variable data bus widths are used in the data path of the architecture, which leads to reduce the
hardware cost and silicon area. Experimental results and
comparisons prove the efficiency of the architecture. Moreover, in terms of computation time, the result shows that the proposed technique is 1000 times faster than the conventional MATLAB reconstruction, while maintaining the quality of the reconstructed image. The results indicate that this architectural design can prove to be a significant tool for SENSE reconstruction in MRI scanners. |
format |
Conference or Workshop Item |
author |
Siddiqui, M.F. Reza, A.W. Kanesan, J. Omer, H. |
author_facet |
Siddiqui, M.F. Reza, A.W. Kanesan, J. Omer, H. |
author_sort |
Siddiqui, M.F. |
title |
A new parameterized architectural design for SENSE reconstruction |
title_short |
A new parameterized architectural design for SENSE reconstruction |
title_full |
A new parameterized architectural design for SENSE reconstruction |
title_fullStr |
A new parameterized architectural design for SENSE reconstruction |
title_full_unstemmed |
A new parameterized architectural design for SENSE reconstruction |
title_sort |
new parameterized architectural design for sense reconstruction |
publishDate |
2014 |
url |
http://eprints.um.edu.my/12967/1/A_New_Parameterized_Architectural.pdf http://eprints.um.edu.my/12967/ |
_version_ |
1643689424784982016 |
score |
13.214268 |