The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat

A study was carried out on the effect of different source thickness (0.5 cm, 0.75 cm, 1.0 cm and 1.25 cm) on a Ge(Li) detector's relative efficiency. The effect of sample density was also studied. It was found that for a particular energy of a gamma photon. the relative efficiency increases as...

Full description

Saved in:
Bibliographic Details
Main Author: Saat, Ahmad
Format: Article
Language:English
Published: Universiti Teknologi MARA, Pahang 1993
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/61419/1/61419.PDF
https://ir.uitm.edu.my/id/eprint/61419/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.61419
record_format eprints
spelling my.uitm.ir.614192023-01-30T00:21:41Z https://ir.uitm.edu.my/id/eprint/61419/ The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat Saat, Ahmad Temperature Spectroscopy A study was carried out on the effect of different source thickness (0.5 cm, 0.75 cm, 1.0 cm and 1.25 cm) on a Ge(Li) detector's relative efficiency. The effect of sample density was also studied. It was found that for a particular energy of a gamma photon. the relative efficiency increases as the thickness decreases. For the range of mass (hence, density) studied it was found that the effect on the relative efficiency is very little. Universiti Teknologi MARA, Pahang 1993 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/61419/1/61419.PDF The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat. (1993) GADING Jurnal Akademik ITM Cawangan Pahang, 1 (1): 1. pp. 1-8. ISSN 0128-5599
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Temperature
Spectroscopy
spellingShingle Temperature
Spectroscopy
Saat, Ahmad
The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
description A study was carried out on the effect of different source thickness (0.5 cm, 0.75 cm, 1.0 cm and 1.25 cm) on a Ge(Li) detector's relative efficiency. The effect of sample density was also studied. It was found that for a particular energy of a gamma photon. the relative efficiency increases as the thickness decreases. For the range of mass (hence, density) studied it was found that the effect on the relative efficiency is very little.
format Article
author Saat, Ahmad
author_facet Saat, Ahmad
author_sort Saat, Ahmad
title The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
title_short The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
title_full The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
title_fullStr The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
title_full_unstemmed The effect of source thickness and density on Ge (Li) detection efficiency / Ahmad Saat
title_sort effect of source thickness and density on ge (li) detection efficiency / ahmad saat
publisher Universiti Teknologi MARA, Pahang
publishDate 1993
url https://ir.uitm.edu.my/id/eprint/61419/1/61419.PDF
https://ir.uitm.edu.my/id/eprint/61419/
_version_ 1756687553620082688
score 13.160551