Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib

Ascorbic acid is a water-soluble vitamin and commonly known as Vitamin. Human cannot synthesize the ascorbic acid. It is naturally abundance in citrus fruits and most of the vegetables. Hence, these fruits and vegetables become main source of ascorbic acid to meet requirement of dietary intake. T...

Full description

Saved in:
Bibliographic Details
Main Author: Suib, Nur Anis Fadhilah
Format: Student Project
Language:English
Published: Faculty Of Applied Sciences 2019
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/25369/1/PPb_NUR%20ANIS%20FADHILAH%20SUIB%20AS%20C%2019_5.PDF
http://ir.uitm.edu.my/id/eprint/25369/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.25369
record_format eprints
spelling my.uitm.ir.253692019-08-28T07:17:44Z http://ir.uitm.edu.my/id/eprint/25369/ Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib Suib, Nur Anis Fadhilah Extraction (Chemistry) Ascorbic acid is a water-soluble vitamin and commonly known as Vitamin. Human cannot synthesize the ascorbic acid. It is naturally abundance in citrus fruits and most of the vegetables. Hence, these fruits and vegetables become main source of ascorbic acid to meet requirement of dietary intake. The differential pulse anodic stripping voltammetric (DPASV) technique has been proposed for ascorbic acid analysis in commercial Roselle juices based on the electrochemical oxidation of the ascorbic acid at glassy carbon electrode (GCE). Phosphate buffer solution (PBS) at pH 5.0 was used as a supporting electrolyte. The parameters used were ~ =+0 Vt Er'" 0.8 V, tacc = 60 S, v - 0.05000 V/s, Eacc = 0 V and pulse amplitude =0.15000 V. The calibration graph obtained shows a linear reqion between peak height and ascorbic acid concentration. The equation of the calibration graph was y = 83.168x + 284.03 with regression coefficient (R2) of 0.9995. The limits of detection (LODs) were found to be 0.25 rmg L-1 0.59 mg L-I and 0.10 mg Lol. The precision in term of relative standard deviation (RSD) were 0.69 %, 0.18 % and 0.17 % for three consecutive days. The recovery of ascorbic acid content in the commercial Roselle juices were 86.53 ± 4.27% for 25 mg L-I 92.53 ± 4.71 % for 50 mg L-l and 96.73 ± 4.12 % for 100 mg L-l. It can be concluded that the proposed technique is precise, accurate, rugged, cheap, fast and has potential to be an alternative method for further analysis of ascorbic acid in the commercial Roselle juices. Faculty Of Applied Sciences 2019 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/25369/1/PPb_NUR%20ANIS%20FADHILAH%20SUIB%20AS%20C%2019_5.PDF Suib, Nur Anis Fadhilah (2019) Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Extraction (Chemistry)
spellingShingle Extraction (Chemistry)
Suib, Nur Anis Fadhilah
Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
description Ascorbic acid is a water-soluble vitamin and commonly known as Vitamin. Human cannot synthesize the ascorbic acid. It is naturally abundance in citrus fruits and most of the vegetables. Hence, these fruits and vegetables become main source of ascorbic acid to meet requirement of dietary intake. The differential pulse anodic stripping voltammetric (DPASV) technique has been proposed for ascorbic acid analysis in commercial Roselle juices based on the electrochemical oxidation of the ascorbic acid at glassy carbon electrode (GCE). Phosphate buffer solution (PBS) at pH 5.0 was used as a supporting electrolyte. The parameters used were ~ =+0 Vt Er'" 0.8 V, tacc = 60 S, v - 0.05000 V/s, Eacc = 0 V and pulse amplitude =0.15000 V. The calibration graph obtained shows a linear reqion between peak height and ascorbic acid concentration. The equation of the calibration graph was y = 83.168x + 284.03 with regression coefficient (R2) of 0.9995. The limits of detection (LODs) were found to be 0.25 rmg L-1 0.59 mg L-I and 0.10 mg Lol. The precision in term of relative standard deviation (RSD) were 0.69 %, 0.18 % and 0.17 % for three consecutive days. The recovery of ascorbic acid content in the commercial Roselle juices were 86.53 ± 4.27% for 25 mg L-I 92.53 ± 4.71 % for 50 mg L-l and 96.73 ± 4.12 % for 100 mg L-l. It can be concluded that the proposed technique is precise, accurate, rugged, cheap, fast and has potential to be an alternative method for further analysis of ascorbic acid in the commercial Roselle juices.
format Student Project
author Suib, Nur Anis Fadhilah
author_facet Suib, Nur Anis Fadhilah
author_sort Suib, Nur Anis Fadhilah
title Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
title_short Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
title_full Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
title_fullStr Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
title_full_unstemmed Voltammetric technique for ascorbic acid analysis in commercial roselle juices / Nur Anis Fadhilah Suib
title_sort voltammetric technique for ascorbic acid analysis in commercial roselle juices / nur anis fadhilah suib
publisher Faculty Of Applied Sciences
publishDate 2019
url http://ir.uitm.edu.my/id/eprint/25369/1/PPb_NUR%20ANIS%20FADHILAH%20SUIB%20AS%20C%2019_5.PDF
http://ir.uitm.edu.my/id/eprint/25369/
_version_ 1685649988354310144
score 13.18916