Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management

Combating Pressure Ulcer (PU) prevalence have proven to be time and cost-intensive. Higher risk of morbidity is seen from slight negligence with immobilized subjects. Best PU prevention mostly revolves around constant pressure unloading once above 32mmHg which is detrimental on the blood capillarie...

Full description

Saved in:
Bibliographic Details
Main Authors: Fajingbesi, Fawwaz Eniola, Azman, Amelia Wong, Ahmad, Zuraida, Olanrewaju, Rashidah Funke, Ibrahimy, Muhammad Ibn, Mohd. Mustafah, Yasir
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2020
Subjects:
Online Access:http://irep.iium.edu.my/78377/7/78377%20Low%20Cost%20Piezoresistive%20Pressure.pdf
http://irep.iium.edu.my/78377/8/78377%20Low%20Cost%20Piezoresistive%20Pressure%20SCOPUS.pdf
http://irep.iium.edu.my/78377/
https://ieeexplore.ieee.org/abstract/document/8952007
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.78377
record_format dspace
spelling my.iium.irep.783772020-03-10T01:04:20Z http://irep.iium.edu.my/78377/ Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management Fajingbesi, Fawwaz Eniola Azman, Amelia Wong Ahmad, Zuraida Olanrewaju, Rashidah Funke Ibrahimy, Muhammad Ibn Mohd. Mustafah, Yasir T Technology (General) Combating Pressure Ulcer (PU) prevalence have proven to be time and cost-intensive. Higher risk of morbidity is seen from slight negligence with immobilized subjects. Best PU prevention mostly revolves around constant pressure unloading once above 32mmHg which is detrimental on the blood capillaries and surrounding tissues. Thus, real-time pressure monitoring and unloading protocol are highly favored with PU at-risk patients. It may either be manual (Clinician/Caregivers following established protocols from PU Risk Assesment Tools (RATs)) or semi- to fully automated systems incorporating pressure monitoring devices. These existing pressure sensing systems are either rigid and or couldn’t support full-time integration without increasing mechanical stress and shear force imposed upon contact interface due to their slippery polymeric surface material (PET/PVC/PDMS/PI etc) used for sensor packaging to increase flexibility and conformity on diverse surface shapes. They have similarly compromised on breathability and hydrophilic material selection conducive in pressure ulcer prevention and management. Although there have been results from recent research producing fully textile sensors, their cost and instability are still on the high side. Thus, this paper introduces rapid prototyping compatible low-cost PU prevention and management friendly textile pressure sensing device compatible with existing actuation or electrical stimulation system, which will relay in order to allow targeted pressure relief according to feedbacks from the pressure monitoring system. A prototype Flexi-semi breathable, piezoresistive pressure sensor matrix has been fabricated based on a polymeric foil (polyolefins) impregnated with carbon black (Velostat) sandwich between a pair of ultra-thin copper-lined bamboo fabric. With an overall height of about 800 µm, the surface area of 210 * 297 mm, a total of 140 pressure sensor nodes are enclosed evenly to measure pressure directly, without any deformation elements, such as in cantilever or a deformation membrane. IEEE 2020-01-09 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/78377/7/78377%20Low%20Cost%20Piezoresistive%20Pressure.pdf application/pdf en http://irep.iium.edu.my/78377/8/78377%20Low%20Cost%20Piezoresistive%20Pressure%20SCOPUS.pdf Fajingbesi, Fawwaz Eniola and Azman, Amelia Wong and Ahmad, Zuraida and Olanrewaju, Rashidah Funke and Ibrahimy, Muhammad Ibn and Mohd. Mustafah, Yasir (2020) Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management. In: 2019 7th International Conference on Mechatronics Engineering (ICOM) 2019, 30th–31st October 2019, Putrajaya. https://ieeexplore.ieee.org/abstract/document/8952007 10.1109/ICOM47790.2019.8952007
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic T Technology (General)
spellingShingle T Technology (General)
Fajingbesi, Fawwaz Eniola
Azman, Amelia Wong
Ahmad, Zuraida
Olanrewaju, Rashidah Funke
Ibrahimy, Muhammad Ibn
Mohd. Mustafah, Yasir
Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
description Combating Pressure Ulcer (PU) prevalence have proven to be time and cost-intensive. Higher risk of morbidity is seen from slight negligence with immobilized subjects. Best PU prevention mostly revolves around constant pressure unloading once above 32mmHg which is detrimental on the blood capillaries and surrounding tissues. Thus, real-time pressure monitoring and unloading protocol are highly favored with PU at-risk patients. It may either be manual (Clinician/Caregivers following established protocols from PU Risk Assesment Tools (RATs)) or semi- to fully automated systems incorporating pressure monitoring devices. These existing pressure sensing systems are either rigid and or couldn’t support full-time integration without increasing mechanical stress and shear force imposed upon contact interface due to their slippery polymeric surface material (PET/PVC/PDMS/PI etc) used for sensor packaging to increase flexibility and conformity on diverse surface shapes. They have similarly compromised on breathability and hydrophilic material selection conducive in pressure ulcer prevention and management. Although there have been results from recent research producing fully textile sensors, their cost and instability are still on the high side. Thus, this paper introduces rapid prototyping compatible low-cost PU prevention and management friendly textile pressure sensing device compatible with existing actuation or electrical stimulation system, which will relay in order to allow targeted pressure relief according to feedbacks from the pressure monitoring system. A prototype Flexi-semi breathable, piezoresistive pressure sensor matrix has been fabricated based on a polymeric foil (polyolefins) impregnated with carbon black (Velostat) sandwich between a pair of ultra-thin copper-lined bamboo fabric. With an overall height of about 800 µm, the surface area of 210 * 297 mm, a total of 140 pressure sensor nodes are enclosed evenly to measure pressure directly, without any deformation elements, such as in cantilever or a deformation membrane.
format Conference or Workshop Item
author Fajingbesi, Fawwaz Eniola
Azman, Amelia Wong
Ahmad, Zuraida
Olanrewaju, Rashidah Funke
Ibrahimy, Muhammad Ibn
Mohd. Mustafah, Yasir
author_facet Fajingbesi, Fawwaz Eniola
Azman, Amelia Wong
Ahmad, Zuraida
Olanrewaju, Rashidah Funke
Ibrahimy, Muhammad Ibn
Mohd. Mustafah, Yasir
author_sort Fajingbesi, Fawwaz Eniola
title Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
title_short Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
title_full Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
title_fullStr Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
title_full_unstemmed Low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
title_sort low cost piezoresistive pressure sensor matrix for pressure ulcer prevention and management
publisher IEEE
publishDate 2020
url http://irep.iium.edu.my/78377/7/78377%20Low%20Cost%20Piezoresistive%20Pressure.pdf
http://irep.iium.edu.my/78377/8/78377%20Low%20Cost%20Piezoresistive%20Pressure%20SCOPUS.pdf
http://irep.iium.edu.my/78377/
https://ieeexplore.ieee.org/abstract/document/8952007
_version_ 1662753813344288768
score 13.18916