Analysis of Milk Fat Deposition Using Avrami Kinetics Model

The deposition of milk was conducted to determine the crystallinity content of milk fat which will affect on the mass production and storage of the products where it would be undergone other process for various purposes whether fresh or processed products. Kinetics analyses were conducted to stud...

Full description

Saved in:
Bibliographic Details
Main Author: Abu Bakar, Azharun Saidi Hamzah
Format: Final Year Project
Language:English
Published: IRC 2012
Subjects:
Online Access:http://utpedia.utp.edu.my/15273/1/2012%20Bachelor%20-%20Analysis%20Of%20Milk%20Fat%20Deposition%20Using%20AVRAMI%20Kinetics%20Model.pdf
http://utpedia.utp.edu.my/15273/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utp-utpedia.15273
record_format eprints
spelling my-utp-utpedia.152732017-01-25T09:40:29Z http://utpedia.utp.edu.my/15273/ Analysis of Milk Fat Deposition Using Avrami Kinetics Model Abu Bakar, Azharun Saidi Hamzah TP Chemical technology The deposition of milk was conducted to determine the crystallinity content of milk fat which will affect on the mass production and storage of the products where it would be undergone other process for various purposes whether fresh or processed products. Kinetics analyses were conducted to study the deposition of the milk whereas most of the deposits are rich in milk fat. Different heating and cooling temperature, equipments or medium of the milk fat deposition were used and effect of sample size had been selected as the parameter for the experiment. Through the analysis, milks that deposit under fast cooling yielded a higher Avrami constant (k), and a lower Avrami exponent (n) compared with the slow cooling sample. Different heating temperature also gives different time for the milk fat to start to deposit and time required for the milk fat to fully crystallized/deposited. Through experiment, higher heating temperature leads to lower Avrami constant (k), and a higher Avrami exponent (n) while for lower cooling temperature, it resulted in opposite effects. For 80°C to 0°C,k and n value is 2.655 and 0.29 while for 60°C to 0°C, the k and n value is 2.951 and 0.235. Experimental of different equipment shows the higher conductivity equipment (metal cup) produce higher k and lower n value which is 2.655 and 0.29 compared to beaker which is 2.2909 and 0.317. For experiment of different sample size, 25 g shows higher k and lower n value which is 3.5727 and 0.201, compared to 100 g which is 1.799 and 0.429 in the same operating condition. IRC 2012-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/15273/1/2012%20Bachelor%20-%20Analysis%20Of%20Milk%20Fat%20Deposition%20Using%20AVRAMI%20Kinetics%20Model.pdf Abu Bakar, Azharun Saidi Hamzah (2012) Analysis of Milk Fat Deposition Using Avrami Kinetics Model. IRC, Universiti Teknologi PETRONAS.
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Abu Bakar, Azharun Saidi Hamzah
Analysis of Milk Fat Deposition Using Avrami Kinetics Model
description The deposition of milk was conducted to determine the crystallinity content of milk fat which will affect on the mass production and storage of the products where it would be undergone other process for various purposes whether fresh or processed products. Kinetics analyses were conducted to study the deposition of the milk whereas most of the deposits are rich in milk fat. Different heating and cooling temperature, equipments or medium of the milk fat deposition were used and effect of sample size had been selected as the parameter for the experiment. Through the analysis, milks that deposit under fast cooling yielded a higher Avrami constant (k), and a lower Avrami exponent (n) compared with the slow cooling sample. Different heating temperature also gives different time for the milk fat to start to deposit and time required for the milk fat to fully crystallized/deposited. Through experiment, higher heating temperature leads to lower Avrami constant (k), and a higher Avrami exponent (n) while for lower cooling temperature, it resulted in opposite effects. For 80°C to 0°C,k and n value is 2.655 and 0.29 while for 60°C to 0°C, the k and n value is 2.951 and 0.235. Experimental of different equipment shows the higher conductivity equipment (metal cup) produce higher k and lower n value which is 2.655 and 0.29 compared to beaker which is 2.2909 and 0.317. For experiment of different sample size, 25 g shows higher k and lower n value which is 3.5727 and 0.201, compared to 100 g which is 1.799 and 0.429 in the same operating condition.
format Final Year Project
author Abu Bakar, Azharun Saidi Hamzah
author_facet Abu Bakar, Azharun Saidi Hamzah
author_sort Abu Bakar, Azharun Saidi Hamzah
title Analysis of Milk Fat Deposition Using Avrami Kinetics Model
title_short Analysis of Milk Fat Deposition Using Avrami Kinetics Model
title_full Analysis of Milk Fat Deposition Using Avrami Kinetics Model
title_fullStr Analysis of Milk Fat Deposition Using Avrami Kinetics Model
title_full_unstemmed Analysis of Milk Fat Deposition Using Avrami Kinetics Model
title_sort analysis of milk fat deposition using avrami kinetics model
publisher IRC
publishDate 2012
url http://utpedia.utp.edu.my/15273/1/2012%20Bachelor%20-%20Analysis%20Of%20Milk%20Fat%20Deposition%20Using%20AVRAMI%20Kinetics%20Model.pdf
http://utpedia.utp.edu.my/15273/
_version_ 1739832110895595520
score 13.209306