Simultaneous Fault Diagnostics for Three-Shaft Industrial Gas Turbine

The study focused on the development of -gas turbine full- and part-load operation diagnostics. The gas turbine performance model was developed using commercial software and validated using the engine manufacturer data. Upon the validation, fouling, erosion, and variable inlet guide vane drift were...

Full description

Saved in:
Bibliographic Details
Main Authors: Salilew, W.M., Gilani, S.I., Lemma, T.A., Fentaye, A.D., Kyprianidis, K.G.
Format: Article
Published: Multidisciplinary Digital Publishing Institute (MDPI) 2023
Online Access:http://scholars.utp.edu.my/id/eprint/37423/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85169141671&doi=10.3390%2fmachines11080832&partnerID=40&md5=95fd3547ac9f1f7360af5507b9dff14c
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The study focused on the development of -gas turbine full- and part-load operation diagnostics. The gas turbine performance model was developed using commercial software and validated using the engine manufacturer data. Upon the validation, fouling, erosion, and variable inlet guide vane drift were simulated to generate faulty data for the diagnostics development. Because the data from the model was noise-free, sensor noise was added to each of the diagnostic set parameters to reflect the actual scenario of the field operation. The data was normalized. In total, 13 single, and 61 double, classes, including 1 clean class, were prepared and used as input. The number of observations for single faults diagnostics were 1092, which was 84 for each class, and 20,496 for double faults diagnostics, which was 336 for each class. Twenty-eight machine learning techniques were investigated to select the one which outperformed the others, and further investigations were conducted with it. The diagnostics results show that the neural network group exhibited better diagnostic accuracy at both full- and part-load operations. The test results and its comparison with literature results demonstrated that the proposed method has a satisfactory and reliable accuracy in diagnosing the considered fault scenarios. The results are discussed, following the plots. © 2023 by the authors.