Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung

Bulk metallic glass demonstrates superior mechanical properties and excellent bio-mechanical stability compared to routinely used biomaterials like titanium, cobalt-chromium, stainless steel, et cetera. However, the metallic glass surface do not easily adhere to the leaving tissues due to native bio...

Full description

Saved in:
Bibliographic Details
Main Authors: Aliyu, A.A., Abdul-Rani, A.M., Al-Amin, M., Hastuty, S., Razak, M.A., Ali, S., Danish, M., Rubaiee, S., Bin Mahfouz, A., Hamza, A.N.
Format: Article
Published: 2023
Online Access:http://scholars.utp.edu.my/id/eprint/34341/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146775480&doi=10.1002%2fmawe.202200044&partnerID=40&md5=21b96ba44dd67256aafd19e3893c0f75
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scholars.utp.edu.my:34341
record_format eprints
spelling oai:scholars.utp.edu.my:343412023-02-17T12:59:02Z http://scholars.utp.edu.my/id/eprint/34341/ Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung Aliyu, A.A. Abdul-Rani, A.M. Al-Amin, M. Hastuty, S. Razak, M.A. Ali, S. Danish, M. Rubaiee, S. Bin Mahfouz, A. Hamza, A.N. Bulk metallic glass demonstrates superior mechanical properties and excellent bio-mechanical stability compared to routinely used biomaterials like titanium, cobalt-chromium, stainless steel, et cetera. However, the metallic glass surface do not easily adhere to the leaving tissues due to native bio-inert oxide layer, which have poor wear resistance and low hardness. In this current study an innovative method for surface coating of bulk metallic glass by mixing hydroxyapatite powder during electro-discharge machining has been employed. A biomimetic nano-porous bio-ceramic layer of oxides and carbides was deposited on metallic glass surface. The modified surface integrity and composition were investigated by scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction characterization techniques. The characterization results confirmed the formation of a natural bone-like nano-porous surface topography on the metallic glass surface using a novel hydroxyapatite-mixed electro-discharge coating process. In addition, a favourable surface chemistry in the form of bioceramic carbides (zirconium carbide, titanium carbide) and zirconium oxide layers, was achieved. © 2023 Wiley-VCH GmbH. 2023 Article NonPeerReviewed Aliyu, A.A. and Abdul-Rani, A.M. and Al-Amin, M. and Hastuty, S. and Razak, M.A. and Ali, S. and Danish, M. and Rubaiee, S. and Bin Mahfouz, A. and Hamza, A.N. (2023) Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung. Materialwissenschaft und Werkstofftechnik, 54 (1). pp. 129-136. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146775480&doi=10.1002%2fmawe.202200044&partnerID=40&md5=21b96ba44dd67256aafd19e3893c0f75 10.1002/mawe.202200044 10.1002/mawe.202200044 10.1002/mawe.202200044
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Bulk metallic glass demonstrates superior mechanical properties and excellent bio-mechanical stability compared to routinely used biomaterials like titanium, cobalt-chromium, stainless steel, et cetera. However, the metallic glass surface do not easily adhere to the leaving tissues due to native bio-inert oxide layer, which have poor wear resistance and low hardness. In this current study an innovative method for surface coating of bulk metallic glass by mixing hydroxyapatite powder during electro-discharge machining has been employed. A biomimetic nano-porous bio-ceramic layer of oxides and carbides was deposited on metallic glass surface. The modified surface integrity and composition were investigated by scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction characterization techniques. The characterization results confirmed the formation of a natural bone-like nano-porous surface topography on the metallic glass surface using a novel hydroxyapatite-mixed electro-discharge coating process. In addition, a favourable surface chemistry in the form of bioceramic carbides (zirconium carbide, titanium carbide) and zirconium oxide layers, was achieved. © 2023 Wiley-VCH GmbH.
format Article
author Aliyu, A.A.
Abdul-Rani, A.M.
Al-Amin, M.
Hastuty, S.
Razak, M.A.
Ali, S.
Danish, M.
Rubaiee, S.
Bin Mahfouz, A.
Hamza, A.N.
spellingShingle Aliyu, A.A.
Abdul-Rani, A.M.
Al-Amin, M.
Hastuty, S.
Razak, M.A.
Ali, S.
Danish, M.
Rubaiee, S.
Bin Mahfouz, A.
Hamza, A.N.
Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
author_facet Aliyu, A.A.
Abdul-Rani, A.M.
Al-Amin, M.
Hastuty, S.
Razak, M.A.
Ali, S.
Danish, M.
Rubaiee, S.
Bin Mahfouz, A.
Hamza, A.N.
author_sort Aliyu, A.A.
title Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
title_short Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
title_full Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
title_fullStr Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
title_full_unstemmed Deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process Abscheidung biomimetischer biokompatibler Oxide auf metallischen Glasoberflächen durch elektrische Entladungsbeschichtung
title_sort deposition of biomimetic biocompatible oxides on metallic glass surface by electro-discharge coating process abscheidung biomimetischer biokompatibler oxide auf metallischen glasoberflã¤chen durch elektrische entladungsbeschichtung
publishDate 2023
url http://scholars.utp.edu.my/id/eprint/34341/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146775480&doi=10.1002%2fmawe.202200044&partnerID=40&md5=21b96ba44dd67256aafd19e3893c0f75
_version_ 1758580619103698944
score 13.209306