Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant

In most District Cooling DC setups, Vapor Compression Chillers VCC are installed to provide Chilled Water CW for charging the Thermal Energy Storage TES tank or direct CW supply to the DC network.The operation of these VCC systems accounts for the most electrical power supplied to the entire DC plan...

Full description

Saved in:
Bibliographic Details
Main Authors: Amin Abd Majid, M., Cyril Hampo, C., Bt Akmar, A., Haji Ya, H., Mustapha, M.
Format: Article
Published: 2023
Online Access:http://scholars.utp.edu.my/id/eprint/34228/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140721815&doi=10.1007%2f978-981-19-1939-8_34&partnerID=40&md5=8def7113a44533e2ab33eedb032f86e2
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scholars.utp.edu.my:34228
record_format eprints
spelling oai:scholars.utp.edu.my:342282023-01-04T02:54:12Z http://scholars.utp.edu.my/id/eprint/34228/ Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant Amin Abd Majid, M. Cyril Hampo, C. Bt Akmar, A. Haji Ya, H. Mustapha, M. In most District Cooling DC setups, Vapor Compression Chillers VCC are installed to provide Chilled Water CW for charging the Thermal Energy Storage TES tank or direct CW supply to the DC network.The operation of these VCC systems accounts for the most electrical power supplied to the entire DC plant.This strengthens the need to conduct an environmental and cost implication analysis using these systems for refrigeration purposes.A gate-to-gate Life Cycle Assessment LCA and Life cycle Cost LCC methodologies are utilised in this study for these objectives.A case study of four VCC systems installed in a large DC plant in Malaysia is examined.It is observed from the inventory results that the climatic temperature conditions had a significant influence on the monthly cooling demand, energy consumed, environmental impact and cost incurred.The result reveals that fuel choice had the most significant influence on the environmental impact contribution of the use phase.The LCA result of the considered phase (use phase) shows that the carbon footprint per refrigeration is given as 0.05 kg CO2 eq/RTh, while the cost per refrigeration ton of the VCC system is estimated to be MYR 0.005/RTh. © 2023, Institute of Technology PETRONAS Sdn Bhd. 2023 Article NonPeerReviewed Amin Abd Majid, M. and Cyril Hampo, C. and Bt Akmar, A. and Haji Ya, H. and Mustapha, M. (2023) Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant. Lecture Notes in Mechanical Engineering. pp. 427-437. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140721815&doi=10.1007%2f978-981-19-1939-8_34&partnerID=40&md5=8def7113a44533e2ab33eedb032f86e2 10.1007/978-981-19-1939-8₃₄ 10.1007/978-981-19-1939-8₃₄
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In most District Cooling DC setups, Vapor Compression Chillers VCC are installed to provide Chilled Water CW for charging the Thermal Energy Storage TES tank or direct CW supply to the DC network.The operation of these VCC systems accounts for the most electrical power supplied to the entire DC plant.This strengthens the need to conduct an environmental and cost implication analysis using these systems for refrigeration purposes.A gate-to-gate Life Cycle Assessment LCA and Life cycle Cost LCC methodologies are utilised in this study for these objectives.A case study of four VCC systems installed in a large DC plant in Malaysia is examined.It is observed from the inventory results that the climatic temperature conditions had a significant influence on the monthly cooling demand, energy consumed, environmental impact and cost incurred.The result reveals that fuel choice had the most significant influence on the environmental impact contribution of the use phase.The LCA result of the considered phase (use phase) shows that the carbon footprint per refrigeration is given as 0.05 kg CO2 eq/RTh, while the cost per refrigeration ton of the VCC system is estimated to be MYR 0.005/RTh. © 2023, Institute of Technology PETRONAS Sdn Bhd.
format Article
author Amin Abd Majid, M.
Cyril Hampo, C.
Bt Akmar, A.
Haji Ya, H.
Mustapha, M.
spellingShingle Amin Abd Majid, M.
Cyril Hampo, C.
Bt Akmar, A.
Haji Ya, H.
Mustapha, M.
Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
author_facet Amin Abd Majid, M.
Cyril Hampo, C.
Bt Akmar, A.
Haji Ya, H.
Mustapha, M.
author_sort Amin Abd Majid, M.
title Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
title_short Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
title_full Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
title_fullStr Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
title_full_unstemmed Life Cycle Assessment and Economic Analysis of a Vapor Compression System Integrated with a Large District Cooling Plant
title_sort life cycle assessment and economic analysis of a vapor compression system integrated with a large district cooling plant
publishDate 2023
url http://scholars.utp.edu.my/id/eprint/34228/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140721815&doi=10.1007%2f978-981-19-1939-8_34&partnerID=40&md5=8def7113a44533e2ab33eedb032f86e2
_version_ 1754532144758128640
score 13.214268