Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio

LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for invest...

Full description

Saved in:
Bibliographic Details
Main Authors: Raza, A., Shakir Nasif, M., Al-Waked, R.
Format: Article
Published: 2023
Online Access:http://scholars.utp.edu.my/id/eprint/34190/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scholars.utp.edu.my:34190
record_format eprints
spelling oai:scholars.utp.edu.my:341902023-01-04T02:49:44Z http://scholars.utp.edu.my/id/eprint/34190/ Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio Raza, A. Shakir Nasif, M. Al-Waked, R. LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for investigating its performance under Malaysian and Pakistani weather conditions.In this model, desiccant solution concentration has varied from 40 to 50, and inlet humidity ratio of air is increased twice and thrice for observing the effect on sensible as well as latent effectiveness.With desiccant solution concentration 50 increases latent effectiveness by 8.4, while doubling inlet humidity ratio of air enhances latent effectiveness by 1.7 under Malaysian weather condition.In contrast, latent effectiveness is increased by 2.3 with 50 solution concentration and 1.24 by doubling inlet air humidity ratio under Pakistani weather condition.Sensible effectiveness does not vary significantly in all cases. © 2023, Institute of Technology PETRONAS Sdn Bhd. 2023 Article NonPeerReviewed Raza, A. and Shakir Nasif, M. and Al-Waked, R. (2023) Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio. Lecture Notes in Mechanical Engineering. pp. 407-418. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655 10.1007/978-981-19-1939-8₃₂ 10.1007/978-981-19-1939-8₃₂
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for investigating its performance under Malaysian and Pakistani weather conditions.In this model, desiccant solution concentration has varied from 40 to 50, and inlet humidity ratio of air is increased twice and thrice for observing the effect on sensible as well as latent effectiveness.With desiccant solution concentration 50 increases latent effectiveness by 8.4, while doubling inlet humidity ratio of air enhances latent effectiveness by 1.7 under Malaysian weather condition.In contrast, latent effectiveness is increased by 2.3 with 50 solution concentration and 1.24 by doubling inlet air humidity ratio under Pakistani weather condition.Sensible effectiveness does not vary significantly in all cases. © 2023, Institute of Technology PETRONAS Sdn Bhd.
format Article
author Raza, A.
Shakir Nasif, M.
Al-Waked, R.
spellingShingle Raza, A.
Shakir Nasif, M.
Al-Waked, R.
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
author_facet Raza, A.
Shakir Nasif, M.
Al-Waked, R.
author_sort Raza, A.
title Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
title_short Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
title_full Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
title_fullStr Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
title_full_unstemmed Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
title_sort numerical investigation of lamee in different weather conditions by varying solution concentration with air inlet humidity ratio
publishDate 2023
url http://scholars.utp.edu.my/id/eprint/34190/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655
_version_ 1754532139532025856
score 13.211869