Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio
LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for invest...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
2023
|
Online Access: | http://scholars.utp.edu.my/id/eprint/34190/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scholars.utp.edu.my:34190 |
---|---|
record_format |
eprints |
spelling |
oai:scholars.utp.edu.my:341902023-01-04T02:49:44Z http://scholars.utp.edu.my/id/eprint/34190/ Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio Raza, A. Shakir Nasif, M. Al-Waked, R. LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for investigating its performance under Malaysian and Pakistani weather conditions.In this model, desiccant solution concentration has varied from 40 to 50, and inlet humidity ratio of air is increased twice and thrice for observing the effect on sensible as well as latent effectiveness.With desiccant solution concentration 50 increases latent effectiveness by 8.4, while doubling inlet humidity ratio of air enhances latent effectiveness by 1.7 under Malaysian weather condition.In contrast, latent effectiveness is increased by 2.3 with 50 solution concentration and 1.24 by doubling inlet air humidity ratio under Pakistani weather condition.Sensible effectiveness does not vary significantly in all cases. © 2023, Institute of Technology PETRONAS Sdn Bhd. 2023 Article NonPeerReviewed Raza, A. and Shakir Nasif, M. and Al-Waked, R. (2023) Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio. Lecture Notes in Mechanical Engineering. pp. 407-418. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655 10.1007/978-981-19-1939-8₃₂ 10.1007/978-981-19-1939-8₃₂ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
LAMEE is an indirect contact air dehumidifier, and it also works as a solution regenerator.It has resolved carry over problem of desiccant solution by using a semi-permeable membrane which is permeable to water vapours only.A numerical model of cross flow configuration LAMEE has been made for investigating its performance under Malaysian and Pakistani weather conditions.In this model, desiccant solution concentration has varied from 40 to 50, and inlet humidity ratio of air is increased twice and thrice for observing the effect on sensible as well as latent effectiveness.With desiccant solution concentration 50 increases latent effectiveness by 8.4, while doubling inlet humidity ratio of air enhances latent effectiveness by 1.7 under Malaysian weather condition.In contrast, latent effectiveness is increased by 2.3 with 50 solution concentration and 1.24 by doubling inlet air humidity ratio under Pakistani weather condition.Sensible effectiveness does not vary significantly in all cases. © 2023, Institute of Technology PETRONAS Sdn Bhd. |
format |
Article |
author |
Raza, A. Shakir Nasif, M. Al-Waked, R. |
spellingShingle |
Raza, A. Shakir Nasif, M. Al-Waked, R. Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
author_facet |
Raza, A. Shakir Nasif, M. Al-Waked, R. |
author_sort |
Raza, A. |
title |
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
title_short |
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
title_full |
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
title_fullStr |
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
title_full_unstemmed |
Numerical Investigation of LAMEE in Different Weather Conditions by Varying Solution Concentration with Air Inlet Humidity Ratio |
title_sort |
numerical investigation of lamee in different weather conditions by varying solution concentration with air inlet humidity ratio |
publishDate |
2023 |
url |
http://scholars.utp.edu.my/id/eprint/34190/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140785029&doi=10.1007%2f978-981-19-1939-8_32&partnerID=40&md5=32a8da9286acea216b322a80823e8655 |
_version_ |
1754532139532025856 |
score |
13.211869 |