A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications
Whether the product is a surgical instrument, an orthopaedic implant or a heart valve, it is crucial to meet the criteria of hygiene, durability and protection that are extremely high.Nevertheless, it is quite unlikely for a metal to fully demonstrate all the desired properties.Recently, researchers...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Springer Science and Business Media Deutschland GmbH
2023
|
Online Access: | http://scholars.utp.edu.my/id/eprint/34180/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140801338&doi=10.1007%2f978-981-19-1939-8_61&partnerID=40&md5=b6bff7cd13617f9ddd2c5394decc8f1a |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scholars.utp.edu.my:34180 |
---|---|
record_format |
eprints |
spelling |
oai:scholars.utp.edu.my:341802023-01-04T02:47:32Z http://scholars.utp.edu.my/id/eprint/34180/ A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications Ahmed, I. Ahmad, A. Abdul-Rani, A.M. Tasnim, N. Al-Amin, M. Whether the product is a surgical instrument, an orthopaedic implant or a heart valve, it is crucial to meet the criteria of hygiene, durability and protection that are extremely high.Nevertheless, it is quite unlikely for a metal to fully demonstrate all the desired properties.Recently, researchers have focused on coating bio-friendly materials over these tools in order to achieve desired durability and further ensure their safety and reliability.Among the numerous prevailing coating techniques, Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) coating techniques attain most of the requirements which are desirable for bioimplants and medical instruments.The aim of this review is to show the constructive comparisons between PVD and PEO coatings based on their tribomechanical properties, corrosion resistance and antibacterial characteristics leading to compatibility in biomedical applications.These coatings have positive effects on the biocompatibility and tribological properties of implant surfaces.These coatings have been characterized by scanning electron microscope (SEM), wear track morphology, potentiodynamic polarization test and antimicrobial tests. © 2023, Institute of Technology PETRONAS Sdn Bhd. Springer Science and Business Media Deutschland GmbH 2023 Article NonPeerReviewed Ahmed, I. and Ahmad, A. and Abdul-Rani, A.M. and Tasnim, N. and Al-Amin, M. (2023) A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications. Lecture Notes in Mechanical Engineering. pp. 813-829. ISSN 21954356 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140801338&doi=10.1007%2f978-981-19-1939-8_61&partnerID=40&md5=b6bff7cd13617f9ddd2c5394decc8f1a 10.1007/978-981-19-1939-8₆₁ 10.1007/978-981-19-1939-8₆₁ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Whether the product is a surgical instrument, an orthopaedic implant or a heart valve, it is crucial to meet the criteria of hygiene, durability and protection that are extremely high.Nevertheless, it is quite unlikely for a metal to fully demonstrate all the desired properties.Recently, researchers have focused on coating bio-friendly materials over these tools in order to achieve desired durability and further ensure their safety and reliability.Among the numerous prevailing coating techniques, Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) coating techniques attain most of the requirements which are desirable for bioimplants and medical instruments.The aim of this review is to show the constructive comparisons between PVD and PEO coatings based on their tribomechanical properties, corrosion resistance and antibacterial characteristics leading to compatibility in biomedical applications.These coatings have positive effects on the biocompatibility and tribological properties of implant surfaces.These coatings have been characterized by scanning electron microscope (SEM), wear track morphology, potentiodynamic polarization test and antimicrobial tests. © 2023, Institute of Technology PETRONAS Sdn Bhd. |
format |
Article |
author |
Ahmed, I. Ahmad, A. Abdul-Rani, A.M. Tasnim, N. Al-Amin, M. |
spellingShingle |
Ahmed, I. Ahmad, A. Abdul-Rani, A.M. Tasnim, N. Al-Amin, M. A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
author_facet |
Ahmed, I. Ahmad, A. Abdul-Rani, A.M. Tasnim, N. Al-Amin, M. |
author_sort |
Ahmed, I. |
title |
A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
title_short |
A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
title_full |
A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
title_fullStr |
A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
title_full_unstemmed |
A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications |
title_sort |
comparative review of surface modification technique between physical vapor deposition (pvd) and plasma electrolytic oxidation (peo) for biomedical applications |
publisher |
Springer Science and Business Media Deutschland GmbH |
publishDate |
2023 |
url |
http://scholars.utp.edu.my/id/eprint/34180/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140801338&doi=10.1007%2f978-981-19-1939-8_61&partnerID=40&md5=b6bff7cd13617f9ddd2c5394decc8f1a |
_version_ |
1754532138145808384 |
score |
13.214268 |