Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia

Monitoring and Physico-chemical characterization of ex-mining pools was carried out for 9 months at 15 days interval. Physico-chemical parameters such as pH, electrical conductivity, total suspended solids (TSS), total dissolved solids (TDS), chemical oxygen demand (COD), hardness as well as anions...

Full description

Saved in:
Bibliographic Details
Main Authors: Qadir, D., Mukhtar, H., Keong, L.K.
Format: Article
Published: Malaysian Abstracting and Indexing System 2017
Online Access:http://scholars.utp.edu.my/id/eprint/19528/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032221792&partnerID=40&md5=b31e986f5ba0ee2e70f37ec0cacb9d20
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scholars.utp.edu.my:19528
record_format eprints
spelling oai:scholars.utp.edu.my:195282023-04-11T04:14:36Z http://scholars.utp.edu.my/id/eprint/19528/ Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia Qadir, D. Mukhtar, H. Keong, L.K. Monitoring and Physico-chemical characterization of ex-mining pools was carried out for 9 months at 15 days interval. Physico-chemical parameters such as pH, electrical conductivity, total suspended solids (TSS), total dissolved solids (TDS), chemical oxygen demand (COD), hardness as well as anions including chloride, nitrate, phosphate, sulfate and cations such as calcium, magnesium, tin, lead, iron, nickel, chromium, zinc were investigated. A comparison was also made to National Drinking Water Quality Standards Malaysia (NDWQSM). It was determined that only turbidity, COD and cations exceeded the standard limits set for drinking water. Other parameters such as pH, electrical conductivity, anions and hardness remained within the allowable limits during the sampling period. It is revealed that COD values (up to 180 mg/L) were found above the permissible limits (10 mg/L). Moreover, among all cations investigated here, lead (up to 0.19 mg/L), nickel (up to 0.05 mg/L) and iron (up to 1.286 mg/L) were present in hazardous amount whereas tin was noted to be 25 mg/L. It was deduced that these ex-mining pools could be a potential fresh water resource only after suitable treatment such as membrane filtration and adsorption could be applied to remove the contaminants and heavy metals. Malaysian Abstracting and Indexing System 2017 Article PeerReviewed Qadir, D. and Mukhtar, H. and Keong, L.K. (2017) Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia. Malaysian Journal of Science, 36 (1). pp. 32-46. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032221792&partnerID=40&md5=b31e986f5ba0ee2e70f37ec0cacb9d20
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Monitoring and Physico-chemical characterization of ex-mining pools was carried out for 9 months at 15 days interval. Physico-chemical parameters such as pH, electrical conductivity, total suspended solids (TSS), total dissolved solids (TDS), chemical oxygen demand (COD), hardness as well as anions including chloride, nitrate, phosphate, sulfate and cations such as calcium, magnesium, tin, lead, iron, nickel, chromium, zinc were investigated. A comparison was also made to National Drinking Water Quality Standards Malaysia (NDWQSM). It was determined that only turbidity, COD and cations exceeded the standard limits set for drinking water. Other parameters such as pH, electrical conductivity, anions and hardness remained within the allowable limits during the sampling period. It is revealed that COD values (up to 180 mg/L) were found above the permissible limits (10 mg/L). Moreover, among all cations investigated here, lead (up to 0.19 mg/L), nickel (up to 0.05 mg/L) and iron (up to 1.286 mg/L) were present in hazardous amount whereas tin was noted to be 25 mg/L. It was deduced that these ex-mining pools could be a potential fresh water resource only after suitable treatment such as membrane filtration and adsorption could be applied to remove the contaminants and heavy metals.
format Article
author Qadir, D.
Mukhtar, H.
Keong, L.K.
spellingShingle Qadir, D.
Mukhtar, H.
Keong, L.K.
Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
author_facet Qadir, D.
Mukhtar, H.
Keong, L.K.
author_sort Qadir, D.
title Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
title_short Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
title_full Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
title_fullStr Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
title_full_unstemmed Monitoring and physico-chemical assessment of ex-mining pools in Perak, Malaysia
title_sort monitoring and physico-chemical assessment of ex-mining pools in perak, malaysia
publisher Malaysian Abstracting and Indexing System
publishDate 2017
url http://scholars.utp.edu.my/id/eprint/19528/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032221792&partnerID=40&md5=b31e986f5ba0ee2e70f37ec0cacb9d20
_version_ 1762964042221092864
score 13.214268