Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance

Hotelling T² control chart is an effective tool in statistical process control for multivariate environment. However, the performance of traditional Hotelling T² control chart using classical location and scatter estimators is usually marred by the masking and swamping effects. In order to alleviate...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Hazlina, Ali
التنسيق: أطروحة
اللغة:English
English
منشور في: 2013
الموضوعات:
الوصول للمادة أونلاين:https://etd.uum.edu.my/3870/1/s91512.pdf
https://etd.uum.edu.my/3870/7/s91512.pdf
https://etd.uum.edu.my/3870/
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
id my.uum.etd.3870
record_format eprints
spelling my.uum.etd.38702022-10-06T07:06:04Z https://etd.uum.edu.my/3870/ Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance Hazlina, Ali QA273-280 Probabilities. Mathematical statistics Hotelling T² control chart is an effective tool in statistical process control for multivariate environment. However, the performance of traditional Hotelling T² control chart using classical location and scatter estimators is usually marred by the masking and swamping effects. In order to alleviate the problem, robust estimators are recommended. The most popular and widely used robust estimator in the Hotelling T² control chart is the minimum covariance determinant (MCD). Recently, a new robust estimator known as minimum vector variance (MVV) was introduced. This estimator possesses high breakdown point, affine equivariance and is superior in terms of computational efficiency. Due to these nice properties, this study proposed to replace the classical estimators with the MVV location and scatter estimators in the construction of Hotelling T² control chart for individual observations in Phase II analysis. Nevertheless, some drawbacks such as inconsistency under normal distribution, biased for small sample size and low efficiency under high breakdown point were discovered. To improve the MVV estimators in terms of consistency and unbiasedness, the MVV scatter estimator was multiplied by consistency and correction factors respectively. To maintain the high breakdown point while having high statistical efficiency, a reweighted version of MVV estimator (RMVV) was proposed. Subsequently, the RMVV estimators were applied in the construction of Hotelling T² control chart. The new robust Hotelling T² chart produced positive impact in detecting outliers while simultaneously controlling false alarm rates. Apart from analysis of simulated data, analysis of real data also found that the new robust Hotelling T² chart was able to detect out of control observations better than the other charts investigated in this study. Based on the good performance on both simulated and real data analysis, the new robust Hotelling T² chart is a good alternative to the existing Hotelling T² charts. 2013 Thesis NonPeerReviewed text en https://etd.uum.edu.my/3870/1/s91512.pdf text en https://etd.uum.edu.my/3870/7/s91512.pdf Hazlina, Ali (2013) Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance. PhD. thesis, Universiti Utara Malaysia.
institution Universiti Utara Malaysia
building UUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Utara Malaysia
content_source UUM Electronic Theses
url_provider http://etd.uum.edu.my/
language English
English
topic QA273-280 Probabilities. Mathematical statistics
spellingShingle QA273-280 Probabilities. Mathematical statistics
Hazlina, Ali
Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
description Hotelling T² control chart is an effective tool in statistical process control for multivariate environment. However, the performance of traditional Hotelling T² control chart using classical location and scatter estimators is usually marred by the masking and swamping effects. In order to alleviate the problem, robust estimators are recommended. The most popular and widely used robust estimator in the Hotelling T² control chart is the minimum covariance determinant (MCD). Recently, a new robust estimator known as minimum vector variance (MVV) was introduced. This estimator possesses high breakdown point, affine equivariance and is superior in terms of computational efficiency. Due to these nice properties, this study proposed to replace the classical estimators with the MVV location and scatter estimators in the construction of Hotelling T² control chart for individual observations in Phase II analysis. Nevertheless, some drawbacks such as inconsistency under normal distribution, biased for small sample size and low efficiency under high breakdown point were discovered. To improve the MVV estimators in terms of consistency and unbiasedness, the MVV scatter estimator was multiplied by consistency and correction factors respectively. To maintain the high breakdown point while having high statistical efficiency, a reweighted version of MVV estimator (RMVV) was proposed. Subsequently, the RMVV estimators were applied in the construction of Hotelling T² control chart. The new robust Hotelling T² chart produced positive impact in detecting outliers while simultaneously controlling false alarm rates. Apart from analysis of simulated data, analysis of real data also found that the new robust Hotelling T² chart was able to detect out of control observations better than the other charts investigated in this study. Based on the good performance on both simulated and real data analysis, the new robust Hotelling T² chart is a good alternative to the existing Hotelling T² charts.
format Thesis
author Hazlina, Ali
author_facet Hazlina, Ali
author_sort Hazlina, Ali
title Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
title_short Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
title_full Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
title_fullStr Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
title_full_unstemmed Efficient and Highly Robust Hotelling T² Control Charts Using Reweighted Mininum Vector Variance
title_sort efficient and highly robust hotelling t² control charts using reweighted mininum vector variance
publishDate 2013
url https://etd.uum.edu.my/3870/1/s91512.pdf
https://etd.uum.edu.my/3870/7/s91512.pdf
https://etd.uum.edu.my/3870/
_version_ 1746212425384853504