Assessment on Pollutant Removal of Interconnected Wet Detention Pond

Best Management Practices (BMPs) have been used worldwide to control urban stormwater runoff. The objective of this paper is to assess the urban wet detention ponds on quality control for commercial and residential development in Denai Alam, Selangor, Malaysia. Field monitoring was conducted in th...

Full description

Saved in:
Bibliographic Details
Main Authors: Takaijudin, Husna, Abd Rauf, Nur Hidayah, Hashim, Ahmad Mustafa
Format: Citation Index Journal
Published: IDOSI Publications 2011
Subjects:
Online Access:http://eprints.utp.edu.my/5564/1/AEJAES_no1_2011.pdf
http://eprints.utp.edu.my/5564/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.5564
record_format eprints
spelling my.utp.eprints.55642017-01-19T08:23:27Z Assessment on Pollutant Removal of Interconnected Wet Detention Pond Takaijudin, Husna Abd Rauf, Nur Hidayah Hashim, Ahmad Mustafa TD Environmental technology. Sanitary engineering TA Engineering (General). Civil engineering (General) Best Management Practices (BMPs) have been used worldwide to control urban stormwater runoff. The objective of this paper is to assess the urban wet detention ponds on quality control for commercial and residential development in Denai Alam, Selangor, Malaysia. Field monitoring was conducted in this study area. Eight water samples were collected at 8 different locations from upstream to downstream of catchment area. All parameters were tested on-site except for TSS which was conducted at laboratory. The value of turbidity increased due to the occurrence of erosion and the side slope of detention pond. Total suspended solid (TSS) removal efficiency of Pond B is between 13 - 24%. However, this pond did not perform well in removing total phosphorus (TP) and ammonia nitrogen (NH -N) due to low concentration of dissolved oxygen. It is indicated 3 that the water samples is classified under Class III of Department of Environment (DOE) Water Quality Classification which further treatment is required. Maintaining the detention pond could reduce pollutant loadings to meet targeted requirements of water quality improvement. IDOSI Publications 2011 Citation Index Journal PeerReviewed application/pdf http://eprints.utp.edu.my/5564/1/AEJAES_no1_2011.pdf Takaijudin, Husna and Abd Rauf, Nur Hidayah and Hashim, Ahmad Mustafa (2011) Assessment on Pollutant Removal of Interconnected Wet Detention Pond. [Citation Index Journal] http://eprints.utp.edu.my/5564/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TD Environmental technology. Sanitary engineering
TA Engineering (General). Civil engineering (General)
spellingShingle TD Environmental technology. Sanitary engineering
TA Engineering (General). Civil engineering (General)
Takaijudin, Husna
Abd Rauf, Nur Hidayah
Hashim, Ahmad Mustafa
Assessment on Pollutant Removal of Interconnected Wet Detention Pond
description Best Management Practices (BMPs) have been used worldwide to control urban stormwater runoff. The objective of this paper is to assess the urban wet detention ponds on quality control for commercial and residential development in Denai Alam, Selangor, Malaysia. Field monitoring was conducted in this study area. Eight water samples were collected at 8 different locations from upstream to downstream of catchment area. All parameters were tested on-site except for TSS which was conducted at laboratory. The value of turbidity increased due to the occurrence of erosion and the side slope of detention pond. Total suspended solid (TSS) removal efficiency of Pond B is between 13 - 24%. However, this pond did not perform well in removing total phosphorus (TP) and ammonia nitrogen (NH -N) due to low concentration of dissolved oxygen. It is indicated 3 that the water samples is classified under Class III of Department of Environment (DOE) Water Quality Classification which further treatment is required. Maintaining the detention pond could reduce pollutant loadings to meet targeted requirements of water quality improvement.
format Citation Index Journal
author Takaijudin, Husna
Abd Rauf, Nur Hidayah
Hashim, Ahmad Mustafa
author_facet Takaijudin, Husna
Abd Rauf, Nur Hidayah
Hashim, Ahmad Mustafa
author_sort Takaijudin, Husna
title Assessment on Pollutant Removal of Interconnected Wet Detention Pond
title_short Assessment on Pollutant Removal of Interconnected Wet Detention Pond
title_full Assessment on Pollutant Removal of Interconnected Wet Detention Pond
title_fullStr Assessment on Pollutant Removal of Interconnected Wet Detention Pond
title_full_unstemmed Assessment on Pollutant Removal of Interconnected Wet Detention Pond
title_sort assessment on pollutant removal of interconnected wet detention pond
publisher IDOSI Publications
publishDate 2011
url http://eprints.utp.edu.my/5564/1/AEJAES_no1_2011.pdf
http://eprints.utp.edu.my/5564/
_version_ 1738655415826120704