Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings

Large scale air conditioning applications such as those in a university are a major energy consumer. With uncertainties in the cost and availability of local and global energy nowadays, studies on optimization of cooling energy in buildings are necessary. The objective of the present work is to anal...

Full description

Saved in:
Bibliographic Details
Main Authors: Sulaiman, S. A., Hassan, A. H.
Format: Citation Index Journal
Published: 2011
Subjects:
Online Access:http://eprints.utp.edu.my/5475/1/Hadi_2024-2029.pdf
http://eprints.utp.edu.my/5475/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.5475
record_format eprints
spelling my.utp.eprints.54752017-01-19T08:22:52Z Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings Sulaiman, S. A. Hassan, A. H. TJ Mechanical engineering and machinery Large scale air conditioning applications such as those in a university are a major energy consumer. With uncertainties in the cost and availability of local and global energy nowadays, studies on optimization of cooling energy in buildings are necessary. The objective of the present work is to analyze the annual cooling energy of highly glazed academic buildings which are located in a university in Malaysia. The outcome of the study would enable further remedial actions in reducing the energy consumption of the buildings’ air conditioning system. The study is conducted by computer simulation using EnergyPlus software to calculate the cooling energy of a selected building or areas. Comparison is made against the rated equipment load (i.e. the air handling unit) installed in the buildings. Since the buildings in the present work are not constructed parallel to each other the effect of building orientations with respect to the sun positions are also studied. The implications of shades such as venetian blind on the cooling energy are investigated in assessing their effectiveness in reducing the cooling energy, apart from providing thermal comfort to the occupants. In the aspect of operation, the present study includes the effects of reducing the set point air temperature and infiltration of outdoor air due to doors that are left open by the occupants. It is found from the present study that there are significant potentials for savings in the cooling energy of the buildings. 2011-04 Citation Index Journal PeerReviewed application/pdf http://eprints.utp.edu.my/5475/1/Hadi_2024-2029.pdf Sulaiman, S. A. and Hassan, A. H. (2011) Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings. [Citation Index Journal] http://eprints.utp.edu.my/5475/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Sulaiman, S. A.
Hassan, A. H.
Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
description Large scale air conditioning applications such as those in a university are a major energy consumer. With uncertainties in the cost and availability of local and global energy nowadays, studies on optimization of cooling energy in buildings are necessary. The objective of the present work is to analyze the annual cooling energy of highly glazed academic buildings which are located in a university in Malaysia. The outcome of the study would enable further remedial actions in reducing the energy consumption of the buildings’ air conditioning system. The study is conducted by computer simulation using EnergyPlus software to calculate the cooling energy of a selected building or areas. Comparison is made against the rated equipment load (i.e. the air handling unit) installed in the buildings. Since the buildings in the present work are not constructed parallel to each other the effect of building orientations with respect to the sun positions are also studied. The implications of shades such as venetian blind on the cooling energy are investigated in assessing their effectiveness in reducing the cooling energy, apart from providing thermal comfort to the occupants. In the aspect of operation, the present study includes the effects of reducing the set point air temperature and infiltration of outdoor air due to doors that are left open by the occupants. It is found from the present study that there are significant potentials for savings in the cooling energy of the buildings.
format Citation Index Journal
author Sulaiman, S. A.
Hassan, A. H.
author_facet Sulaiman, S. A.
Hassan, A. H.
author_sort Sulaiman, S. A.
title Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
title_short Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
title_full Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
title_fullStr Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
title_full_unstemmed Analysis of Annual Cooling Energy Requirements for Glazed Academic Buildings
title_sort analysis of annual cooling energy requirements for glazed academic buildings
publishDate 2011
url http://eprints.utp.edu.my/5475/1/Hadi_2024-2029.pdf
http://eprints.utp.edu.my/5475/
_version_ 1738655408013180928
score 13.209306