Comparative study on combined series active and shunt passive power filter using two different control methods

This paper presents a comparative study of the combined series active and shunt passive power filter, using instantaneous real active and reactive power (p-q) and instantaneous active and reactive current component (id-iq) method. The p-q method has been proposed as the control method for the combin...

Full description

Saved in:
Bibliographic Details
Main Authors: M.F., Romlie, K.N.Md., Hasan
Format: Conference or Workshop Item
Published: 2007
Subjects:
Online Access:http://eprints.utp.edu.my/443/1/paper.pdf
http://www.scopus.com/inward/record.url?eid=2-s2.0-57949106183&partnerID=40&md5=32444362d7afecf19cc6291b99197a7b
http://eprints.utp.edu.my/443/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.443
record_format eprints
spelling my.utp.eprints.4432017-01-19T08:27:07Z Comparative study on combined series active and shunt passive power filter using two different control methods M.F., Romlie K.N.Md., Hasan TK Electrical engineering. Electronics Nuclear engineering This paper presents a comparative study of the combined series active and shunt passive power filter, using instantaneous real active and reactive power (p-q) and instantaneous active and reactive current component (id-iq) method. The p-q method has been proposed as the control method for the combined filter and gives satisfactory performance [2-3] while id-iq method was proven to give better performance for shunt active power filter in harmonic compensation [5]. Two models of a power line with a nonlinear load using p-q and id-iq method are developed using MATLAB-Simulink SimPower System. Models are simulated for three different conditions of supply source; the balanced sinusoidal supply, unbalanced sinusoidal supply and balanced non-sinusoidal supply. The percentage of total harmonic distortion (%THD) of the output current is measured and the waveform is observed. Based on the result, it is verified that the id-iq control method gives a slightly better result for a distorted supply condition. However, both control method has same effectiveness to compensate the harmonic current when the supply is a normal balanced and sinusoidal. ©2007 IEEE. 2007 Conference or Workshop Item NonPeerReviewed application/pdf http://eprints.utp.edu.my/443/1/paper.pdf http://www.scopus.com/inward/record.url?eid=2-s2.0-57949106183&partnerID=40&md5=32444362d7afecf19cc6291b99197a7b M.F., Romlie and K.N.Md., Hasan (2007) Comparative study on combined series active and shunt passive power filter using two different control methods. In: 2007 International Conference on Intelligent and Advanced Systems, ICIAS 2007, 25 November 2007 through 28 November 2007, Kuala Lumpur. http://eprints.utp.edu.my/443/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
M.F., Romlie
K.N.Md., Hasan
Comparative study on combined series active and shunt passive power filter using two different control methods
description This paper presents a comparative study of the combined series active and shunt passive power filter, using instantaneous real active and reactive power (p-q) and instantaneous active and reactive current component (id-iq) method. The p-q method has been proposed as the control method for the combined filter and gives satisfactory performance [2-3] while id-iq method was proven to give better performance for shunt active power filter in harmonic compensation [5]. Two models of a power line with a nonlinear load using p-q and id-iq method are developed using MATLAB-Simulink SimPower System. Models are simulated for three different conditions of supply source; the balanced sinusoidal supply, unbalanced sinusoidal supply and balanced non-sinusoidal supply. The percentage of total harmonic distortion (%THD) of the output current is measured and the waveform is observed. Based on the result, it is verified that the id-iq control method gives a slightly better result for a distorted supply condition. However, both control method has same effectiveness to compensate the harmonic current when the supply is a normal balanced and sinusoidal. ©2007 IEEE.
format Conference or Workshop Item
author M.F., Romlie
K.N.Md., Hasan
author_facet M.F., Romlie
K.N.Md., Hasan
author_sort M.F., Romlie
title Comparative study on combined series active and shunt passive power filter using two different control methods
title_short Comparative study on combined series active and shunt passive power filter using two different control methods
title_full Comparative study on combined series active and shunt passive power filter using two different control methods
title_fullStr Comparative study on combined series active and shunt passive power filter using two different control methods
title_full_unstemmed Comparative study on combined series active and shunt passive power filter using two different control methods
title_sort comparative study on combined series active and shunt passive power filter using two different control methods
publishDate 2007
url http://eprints.utp.edu.my/443/1/paper.pdf
http://www.scopus.com/inward/record.url?eid=2-s2.0-57949106183&partnerID=40&md5=32444362d7afecf19cc6291b99197a7b
http://eprints.utp.edu.my/443/
_version_ 1738655066262339584
score 13.160551