Calibration and Analysis of X Hot-wire Probe Signals
The authors deal with the use of X hot-wire probes for measurements of two velocity components. Using the effective velocity concept, four different analytical expressions for the yaw response of the hot wire signals have been considered. Using a set of reference calibration data the curve-fit accur...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
IoP electronic journals
1990
|
Subjects: | |
Online Access: | http://eprints.utp.edu.my/4109/1/journals http://www.iop.org/EJ/abstract http://eprints.utp.edu.my/4109/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.4109 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.41092011-12-19T00:54:06Z Calibration and Analysis of X Hot-wire Probe Signals Bruun, H. H. Nabhani, Nadir Al-Kayiem, H. H. Fardad, A.A. Khan, M A Hogarth, E TJ Mechanical engineering and machinery QC Physics The authors deal with the use of X hot-wire probes for measurements of two velocity components. Using the effective velocity concept, four different analytical expressions for the yaw response of the hot wire signals have been considered. Using a set of reference calibration data the curve-fit accuracy of the four methods are first investigated. Then the related sum and difference signal analysis methods are compared and finally the velocity component errors caused by uncertainty in the value of the mean yaw angle are established. IoP electronic journals 1990 Article PeerReviewed other http://eprints.utp.edu.my/4109/1/journals http://www.iop.org/EJ/abstract Bruun, H. H. and Nabhani, Nadir and Al-Kayiem, H. H. and Fardad, A.A. and Khan, M A and Hogarth, E (1990) Calibration and Analysis of X Hot-wire Probe Signals. Measurement Science and Technology, 1 (8). pp. 782-785. ISSN 09570233 http://eprints.utp.edu.my/4109/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
topic |
TJ Mechanical engineering and machinery QC Physics |
spellingShingle |
TJ Mechanical engineering and machinery QC Physics Bruun, H. H. Nabhani, Nadir Al-Kayiem, H. H. Fardad, A.A. Khan, M A Hogarth, E Calibration and Analysis of X Hot-wire Probe Signals |
description |
The authors deal with the use of X hot-wire probes for measurements of two velocity components. Using the effective velocity concept, four different analytical expressions for the yaw response of the hot wire signals have been considered. Using a set of reference calibration data the curve-fit accuracy of the four methods are first investigated. Then the related sum and difference signal analysis methods are compared and finally the velocity component errors caused by uncertainty in the value of the mean yaw angle are established. |
format |
Article |
author |
Bruun, H. H. Nabhani, Nadir Al-Kayiem, H. H. Fardad, A.A. Khan, M A Hogarth, E |
author_facet |
Bruun, H. H. Nabhani, Nadir Al-Kayiem, H. H. Fardad, A.A. Khan, M A Hogarth, E |
author_sort |
Bruun, H. H. |
title |
Calibration and Analysis of X Hot-wire Probe Signals |
title_short |
Calibration and Analysis of X Hot-wire Probe Signals |
title_full |
Calibration and Analysis of X Hot-wire Probe Signals |
title_fullStr |
Calibration and Analysis of X Hot-wire Probe Signals |
title_full_unstemmed |
Calibration and Analysis of X Hot-wire Probe Signals |
title_sort |
calibration and analysis of x hot-wire probe signals |
publisher |
IoP electronic journals |
publishDate |
1990 |
url |
http://eprints.utp.edu.my/4109/1/journals http://www.iop.org/EJ/abstract http://eprints.utp.edu.my/4109/ |
_version_ |
1738655320416190464 |
score |