Performance Evaluation of Stratified TES using Sigmoid Dose Response Function

Temperature distribution on the operating stratified thermal energy storage (TES) is commonly available as discrete data. Due to this, it is difficult to conduct performance evaluation based on thermocline profile, because limit points could not be determined accurately. This paper discusses a pract...

Full description

Saved in:
Bibliographic Details
Main Authors: Joko , Joko, A Majid, M Amin
Format: Citation Index Journal
Published: 2011
Subjects:
Online Access:http://eprints.utp.edu.my/3774/1/Performance_Evalutaion_TES%2C_23664-23664.pdf
http://eprints.utp.edu.my/3774/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.3774
record_format eprints
spelling my.utp.eprints.37742017-01-19T08:23:15Z Performance Evaluation of Stratified TES using Sigmoid Dose Response Function Joko , Joko A Majid, M Amin TJ Mechanical engineering and machinery Temperature distribution on the operating stratified thermal energy storage (TES) is commonly available as discrete data. Due to this, it is difficult to conduct performance evaluation based on thermocline profile, because limit points could not be determined accurately. This paper discusses a practical method in determining the performance parameters of stratified TES based on thermocline profile. Non linear regression fitting was adopted to identify the function which could represent temperature distribution profile. The function was used to define performance parameters namely limit points of thermocline, thermocline thickness, lost capacity, integrated capacity, theoretical capacity as well as half cycle of Figure of Merit. Results identified a function which could represent S-curve of temperature distribution, namely Sigmoid Dose Response (SDR) equation. The function was observed to fit the temperature distributions having coefficient determination more than 0.99. Based on evaluations the method was capable to be utilized for evaluation of the performance of the stratified TES. The methods offer an advantage to obtain an exact value of performance parameters. 2011 Citation Index Journal PeerReviewed application/pdf http://eprints.utp.edu.my/3774/1/Performance_Evalutaion_TES%2C_23664-23664.pdf Joko , Joko and A Majid, M Amin (2011) Performance Evaluation of Stratified TES using Sigmoid Dose Response Function. [Citation Index Journal] http://eprints.utp.edu.my/3774/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Joko , Joko
A Majid, M Amin
Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
description Temperature distribution on the operating stratified thermal energy storage (TES) is commonly available as discrete data. Due to this, it is difficult to conduct performance evaluation based on thermocline profile, because limit points could not be determined accurately. This paper discusses a practical method in determining the performance parameters of stratified TES based on thermocline profile. Non linear regression fitting was adopted to identify the function which could represent temperature distribution profile. The function was used to define performance parameters namely limit points of thermocline, thermocline thickness, lost capacity, integrated capacity, theoretical capacity as well as half cycle of Figure of Merit. Results identified a function which could represent S-curve of temperature distribution, namely Sigmoid Dose Response (SDR) equation. The function was observed to fit the temperature distributions having coefficient determination more than 0.99. Based on evaluations the method was capable to be utilized for evaluation of the performance of the stratified TES. The methods offer an advantage to obtain an exact value of performance parameters.
format Citation Index Journal
author Joko , Joko
A Majid, M Amin
author_facet Joko , Joko
A Majid, M Amin
author_sort Joko , Joko
title Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
title_short Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
title_full Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
title_fullStr Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
title_full_unstemmed Performance Evaluation of Stratified TES using Sigmoid Dose Response Function
title_sort performance evaluation of stratified tes using sigmoid dose response function
publishDate 2011
url http://eprints.utp.edu.my/3774/1/Performance_Evalutaion_TES%2C_23664-23664.pdf
http://eprints.utp.edu.my/3774/
_version_ 1738655293559013376
score 13.211869